www.pulsar.pl
PSBEN1012B
5
2.3 Description of PSU’s components and connectors.
Table 1. Elements of the PSU pcb (see Fig. 2).
Element no.
Description
[1]
PANEL – optical indication connector
[2]
P
BAT
; pin - adjustment of battery protection function UVP
•
P
BAT
=
battery protection (disconnection) off
•
P
BAT
=
battery protection (disconnection) on
T
AC
; pins J1, J2 - adjustable time lag of AC power failure indication
•
J1=
, J2=
time lag T= 5s
•
J1=
, J2=
time lag T= 140s
•
J1=
, J2=
time lag T= 17m
•
J1=
, J2=
time lag T= 2h 20m
Caption:
jumper on,
jumper off
Operation without a battery
- In this mode, the automation mode enables adjustments of the PSU output voltage
without failure indication concerning battery operation.
[3]
I
BAT
– pin - battery charging current selection
I
BAT
=0,2 A
I
BAT
=0,6 A
Caption:
jumper on,
jumper off
[4]
START – button (launching the PSU from a battery)
STOP – button (disconnection of the PSU during battery-assisted operation)
[5]
– pin; activation of the acoustic indication
- indication on
- indication off
Caption:
jumper on,
jumper off
[6]
V
ADJ
– potentiometer, DC voltage adjustment
[7]
BUZER – acoustic indicator
[8]
F
BAT
– fuse in the battery circuit
[9]
Connectors:
~AC~ – AC power input
+BAT – DC power battery output
+AUX – DC power output (+AUX= +U, -AUX=GND)
EPS FLT – technical output of AC network absence indication
open
= AC power failure
close
= AC power - O.K.
PSU FLT – technical output of PSU failure
open
= failure
close
= PSU working correctly - O.K.
APS FLT – technical output of battery failure
open
= battery failure
close
= battery O.K.
EXT IN – output of collective failure
[10]
V
EXT
pin – polarisation of EXT IN circuit
[11]
Communication connector
[12]
LEDs – optical indication:
AC
– presence of the AC power
AUX
– DC output voltage
OVL
– PSU overload
PSU
– PSU failure
APS
– battery failure
EXT
– EXT IN output’s status
LB
– battery charge
[13]
OVP
– optical indication for activating the over voltage system