Pulsar AWZ 230 Скачать руководство пользователя страница 18

 
 

PARAMETRY 

TECHNICZNE 

TECHNICAL 

DATA 

TECHNICKÉ 

PARAMETRY 

LES 

PARAMÉTRES 

TECHNIQUES 

 

Napi

ę

cie zasilania 

 

Power supply 

voltage 

Napájecí nap

ě

tí Tension 

d’entrée 

230V/AC 50Hz 

(-/+15%) 

Transformator Transformer Transformátor 

Transformateur 

TRZ 40VA 

(EN-61558-2-6) 

Napi

ę

cie wyj

ś

ciowe 

OUT Vcc – 

min/max 

Output voltage OUT 

Vcc- 

min/max 

Výstupní nap

ě

tí 

OUT Vcc – 

min/max 

Tension de sortie 

OUT Vcc- min/max 

12V÷13,8V/DC 

13,8V/DC – nom. 

(13,3V/DC@2A)

 

Pr

ą

d wyj

ś

ciowy 

OUT -   max 

Output current OUT 

- max 

Proud výstupní 

OUT - max 

Courant  de sortie 

OUT - maxi 

Imax=2A 

(const.) 

Pr

ą

ł

adowania 

akumulatora Iacc – 

max/max 

Battery charging 

current Iacc –

max/max 

Proud nabíjení 

akumulátoru Iacc – 

max/max 

Courant de charge 

de la batterie Iacc - 

max/max 

Iacc= 

~450mA/~900

mA 

 

F2  bezpiecznik w 

obwodzie 

pierwotnym 

transformatora 

F2 fuse in the 

primary windings of 

the transformer 

F2 pojistka v 

prvotním obvodu 

transformátoru 

F2 fusible dans le 

circuit primaire du 

transformateur 

T 315 mA 

(250V) 

Pr

ą

d obwodu 

pierwotnego 

transformatora - 

max 

Current of the 

primary windings of 

the transformer - 

max 

Proud v prvotním 

obvodu 

transformátoru - 

max 

Courant du circuit 

primaire du 

transformateur - 

max 

~ 320 mA 

Zabezpieczenie 

termiczne 

transformatora 

Thermal protection 

of the transformer 

Tepelná ochrana 

transformátoru 

Protection 

thermique du 

transformateur 

130 ºC 

F1 bezpiecznik w 

obwodzie 

akumulatora 

F1 fuse in the 

battery circuit 

F1 pojistka v 

obvodu 

akumulátoru 

F1 fusible dans le 

circuit de la batterie 

F 4A 

Akumulator Battery Akumulátor Batterie 

7Ah/12V 

Obci

ąż

alno

ść

 wyj

ść

 

technicznych 

AW, BS - max 

Technical outputs 

current 

AW, BS - max 

Proudová 

zatížitelnost 

technických výstup

ů

AW, BS - max 

Courant des sorties 

techniques 

AW, BS -max 

50mA@30V 

(max.) 

OC

 

Obci

ąż

alno

ść

 

wyj

ś

cia TAMPER- 

max 

Output current 

TAMPER - max 

 

Proudová 

zatížitelnost  

výstup

ů

 TAMPER - 

max 

Courant des sortie 

TAMPER - max 

 

500mA@30V 

 

Obudowa IP 

Casing IP 

Krytu IP 

Boitier IP 

IP 20 

Temperatura pracy 

Operating 

temperature 

Provozní teplota 

Température de 

travail 

-10ºC÷45ºC

 

Wilgotno

ść

 

wzgl

ę

dna  RH – 

max. 

Relative humidity 

RH –max. 

Relativni vlhkost RH 

– max  

Humidité RH 

 -max 

93 [%] 

Wymiary 

(szer x wys x g

ł

eb) 

Dimensions 

(w x h xd ) 

Rozm

ě

ry 

(š x v x h) 

Dimensions 

(larg.x haut. x 

profon) 

235 x 235 x 98 

(90+8) 

[-/+2] [mm] 

Waga Weight 

Hmotnost Poids 

3.1 [kg] 

 
 
 
 
 
 
 

Содержание AWZ 230

Страница 1: ...ZBPK 13 8V 2A 7Ah AWZ 230 Zasilacz buforowy Buffer power supply unit Z lo n zdroj Alimentation tampon ver PL EN CZ FR 20060725...

Страница 2: ...pi cie w obwodzie zasilaj cym 230V jest od czone 2 Zamontowa zasilacz w wybranym miejscu i doprowadzi przewody po czeniowe 3 Wyj bezpiecznik sieciowy zabezpieczaj cy obw d pierwotny transformatora 15...

Страница 3: ...aniu testu akumulatora 10 min 13 Przy pomocy przycisku STOP 3 w czy lub wy czy dynamiczny test akumulatora Wy czenie testu wy cza r wnie sygnalizacj awarii akumulatora na wyj ciu 14 Na ko kach ZB 2 ok...

Страница 4: ...j cie brak zasilania 230V AC wyj cie typu OC sygnalizuje utrat zasilania 230V AC w stanie normalnym przy zasilaniu 230V wyj cie jest rozwarte w przypadku utraty zasilania zasilacz za czy wyj cie po up...

Страница 5: ...ly unit provides voltage with less noise and shorter time of fault response when compared to a pulse stabilizer The supply unit provides the voltage VDC 12V 13 8V DC and the output current of IMAX 2A...

Страница 6: ...he output becomes disconnected from the mass 7 With the switching pieces Z3 Z4 5 determine the time of disconnecting the battery in the case of battery assisted operation when the voltage on the termi...

Страница 7: ...peration from battery power supply 230 VAC shortage 2 2 signals every 16 s Discharged battery no battery during operation from the mains battery fuse blown 3 Fast signals during 3s Restart of the powe...

Страница 8: ...battery The battery disconnection time is set by jumpers Z3 Z4 Tab 4 Tab 4 4 3 Dynamic test of battery charge Every 10 minutes the unit executes the battery test by lowering the input voltage and mea...

Страница 9: ...pojte ke svorce ozna en symbolem uzemn n Spojen se prov d troj ilov m kabelem se lutozelen m uzem ovac m vodi em PE Nap jec vodi e p ive te izola n pr chodkou k p slu n m svork m transform toru 14 16...

Страница 10: ...ch stav 3 1 Optickou signalizac Po et problikn ut Typ poruchy P ina Pozn mky 1 chyba akumul toru Akumul tor nen nabit akumul tor nen p ipojen pojistka akumul toru je sp len Zkontrolovat spoje a pojis...

Страница 11: ...Tab 3 4 Pr ce z akumul toru 4 1 Start pr ce zdroje z akumul toru Doba provozu p i nap jen z akumul toru z vis na jeho kapacit rovni nabit a zat ovac m proudu Nap klad u typick ho pln nabit ho akumul t...

Страница 12: ...basse tension Avant de commencer l installation il faut faire le bilan de charge pr vue pour l alimentation Pendant une utilisation normale la somme des courants consomm s par les appareils r cepteurs...

Страница 13: ...r le test dynamique de la batterie Tab 2 Le fait de d brancher le test d branche galement la signalisation des avaries de la batterie sur la sortie AW mais ne d branche pas le syst me de protection de...

Страница 14: ...signal toutes les 8s Fonctionnement sur la batterie absence d alimentation 230V AC 2 2 signaux toutes les 16s Batterie insuffisamment charg e absence de batterie pendant le fonctionnement sur secteur...

Страница 15: ...e La dur e de temporisation jusqu au d branchement de la batterie est r gl e l aide des cavaliers Z3 Z4 Tab 4 Tab 4 4 3 Test dynamique de charge de la batterie Toutes les 10 min l appareil proc de un...

Страница 16: ...fig 1...

Страница 17: ...bezpiecznik w obwodzie akumulatora F1 fuse in the battery circuit F1 pojistka v obvodu akumul toru F1 fusible dans le circuit de la batterie 14 230V 0V z cze zasil 230V AC 230V 0V terminals 230V AC 2...

Страница 18: ...ary windings of the transformer max Proud v prvotn m obvodu transform toru max Courant du circuit primaire du transformateur max 320 mA Zabezpieczenie termiczne transformatora Thermal protection of th...

Страница 19: ...t rej dotyczy reklamacja GUARANTEE 24 months from the date of sale 36 months from the date of production THE GUARANTEE IS VALID only upon presenting the sale invoice for the unit for which the claim i...

Отзывы: