www.pulsar.pl POE084824B
GREEN POWER CCTV PoE
5
Output current t
AMB
<30°C
8 x 0,3A – see diagram 1
Output current t
AMB
=40°C
8 x 0,21A – see diagram 1
Ripple voltage
240 mV p-p max.
Battery charging current
0,16A
Current consumption by the PSU
0,2A max. @ 4x7Ah (± 5%)
Short-circuit protection SCP
electronic
Overload protection OLP
8 x F 0,5A or 8 x PTC 0,5A (jumper selectable)
Battery circuit protection SCP and reverse
polarity connection
melting fuse
Overvoltage protection OVP
62,1÷72,9V DC
Deep discharge battery protection UVP
U<37 V (± 5%) – disconnecting the battery terminal
Surge protection
8 x varistor
Antisabotage protection:
- TAMPER output indicating enclosure opening
- microswitch, NC contacts (enclosure closed),
0,5A@50V DC (max.)
Optical indication of operation:
YES – LED lights
Technical outputs:
- FPS technical output indicating output fuse
activation
- OC type, 50mA max.
Normal operation: L state (0V),
failure: H state (hi-Z), (automatic return once the normal
operation is restored)
- relay type: 1A@ 30VDC/50VAC, delay time:
approximately 10 seconds
F1 ÷ F8 fuses
F 0,5A or PTC 0,5A
Mechanical parameters (Table 4).
Enclosure dimensions
300 x 407 x 126 mm (WxHxD)
Mounting
See Fig. 3
Battery housing:
4x7Ah/12V (SLA) max.
Net weight
4,71kg / 5,01kg
Enclosure
DC01 steel plate, 1,0mm, RAL 9003
Closing
Cylindrical screw x 2 (at the front) lock assembly possible
Terminals
Switch mode power supply:
Φ
0,4-2,5 (AWG 26-10)
PoE module:
Φ
0,5-2,1 (AWG 24-12)
AUX1...8 outputs: RJ45 8pin
TAMPER output:
Φ
0,8
Notes
The enclosure has a 15mm distance from the mounting surface so the cables
can be led.
Safety of use (Table 5).
Protection class PN-EN 60950-1:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Insulation electrical strength:
- between input (network) circuit and the output circuits of the PSU
(I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 M
Ω
, 500V/DC
Operation parameters (Table 6).
Operating temperature
-10ºC...+40ºC (see Figure1)
Storing temperature
-20ºC...+60ºC
Relative humidity
20%...90%, no condensation
Vibrations during operation
unacceptable
Surges during operation
unacceptable
Direct insolation
unacceptable
Vibrations and surges during transport
According
to
the
PN-83/T-42106
standard