www.pulsar.pl                                                      POE084824B   

GREEN POWER CCTV PoE

 

 

 

 

4.  Connect  the  network  cables  (Ethernet)  to  the  PoE module:  supply voltage  is  present  only  at  the  AUX  sockets 
and the cameras should be connected to them. Pin assignment of the AUX and IN sockets is shown in the Figure 
4: 
 

 

 

Fig. 4 Pin assignment of the AUX and IN connectors. 

 
5. Use the F1/PTC1 ÷ F8/PTC8 jumpers to select the type of short circuit / overload protection of individual circuits. 
Jumper in the Fx position – melting fuse activation, PTCx – PTC fuse activation. 
6. If needed, the following technical connections can be made: 
- FPS technical output of the PSU status – indicates the voltage loss at any of the outputs (AUX1 ÷ AUX8). 
TAMPER indicating enclosure opening. 
7. Check the power supply output voltage: 
- output voltage of the unloaded power supply without a battery should amount to U=54V DC. 
8. Connect the batteries in series according to the color markings: 
- battery output (+V): BAT+ cable/ red 
- battery output (0V): BAT- cable / black 
9. Check the optical indication of the PSU status: green LED light on the PoE module. 
10. Close the cover after installing and checking the operation of the power supply. 

 
3.  Power supply operation indication. 

 

3.1. Optical indication. 

The PSU has 11 LED lights at the front panel: 
 

 

 
 

 

 
 

 

 
 

 

RED LED: 

 

on – The PSU supplied with 230V AC voltage 

 

off – no 230V AC mains supply 

 
RED LED: 

 

on – DC voltage at the output of the switch mode PSU  

 

off – no DC voltage at the output of the switch mode PSU 

 
RED LED: 

 

on – fuse failure at one of the AUX1…AUX8 outputs 

 

off – no failure 

 

 
 
GREEN LED: 

 

on – DC voltage at the AUX1…AUX8 output 

 

off – no DC voltage at the AUX1…AUX8 output 

 

 
 

Additionally, the PSU is fitted with LED lights inside the enclosure – see Fig. 2 and 3: 
L

AC

 red LED (Fig. 2, component 1) is permanently illuminated during normal operation (AC power ON).  

No AC power is indicated by turning off the L

AC 

LED. 

L

IN

 green LED (Fig. 2, component 1) indicates DC voltage at the PoE module input. During normal operation (DC 

supply) the LED is permanently illuminated. No DC no DC voltage at the module input is indicated by turning off the 
L

IN 

LED.  

Содержание 54V/8x03A/4x7Ah

Страница 1: ...POE084824B v 1 0 PoE 54V 8x0 3A 4x7Ah Switch mode buffer power supply unit for CCTV EN Edition 1 from 26 11 2013 Supersedes the edition GREEN POWER CCTV PoE...

Страница 2: ...aintenance 1 Technical description 1 1 General description The PSU is designed for supply of up to 8 webcams requiring stabilized voltage of 48V DC 15 The PSU supplies voltage of 54V DC and total curr...

Страница 3: ...ation input 3 F1 F8 fuses in the AUX1 AUX8 F500mA circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L8 voltage indication at the AUX outputs during normal operation these LED...

Страница 4: ...black 6 TAMPER microswitch contacts of antisabotage protection NC Tab 2 Components of the PSU see Fig 3 1 4 Technical parameters electrical parameters Table 3 mechanical parameters Table 4 safety of...

Страница 5: ...ical parameters Table 4 Enclosure dimensions 300 x 407 x 126 mm WxHxD Mounting See Fig 3 Battery housing 4x7Ah 12V SLA max Net weight 4 71kg 5 01kg Enclosure DC01 steel plate 1 0mm RAL 9003 Closing Cy...

Страница 6: ...shall be made in accordance with applicable standards and regulations The PSU is designed for 10Mbit s and 100Mbit s Ethernet network so called Fast Ethernet However it can not be used for a 1000 Mbi...

Страница 7: ...red battery output 0V BAT cable black 9 Check the optical indication of the PSU status green LED light on the PoE module 10 Close the cover after installing and checking the operation of the power su...

Страница 8: ...ly Fig 6 Electrical diagram of the relay output CAUTION The arrangement of contacts at the figure 6 shows a potential free status of the relay which is equivalent to a state with no voltage at any of...

Страница 9: ...ration the battery will be disconnected 4 3 Maintenance All maintenance procedures can be performed after disconnecting the power supply from the power network The PSU does not require any specific ma...

Страница 10: ...service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...

Отзывы: