P814 Miscellaneous Messages
This parameter determines whether notification messages are displayed on
the auxiliary line of the display in run mode when a miscellaneous relay is
switched on or off. The message is in the form “Clock ON”.
OPTION
DESCRIPTION
0 = No (Default)
Miscellaneous messages
will not
be displayed
1= Yes
Miscellaneous messages
will
be displayed
P815 Auxiliary Source
This parameter determines whether the instantaneous velocity readings are
displayed on the auxiliary line of the display in run mode.
OPTION
DESCRIPTION
0 = Off (Default)
Auxiliary display not used to display
measurement readings.
2 = Xducer 1
Displays level from transducer 1
3 = Xducer 2
Displays level from transducer 2
4 = Rate
Displays Inflow (I) and pumping rate (P)
P816 Totaliser (R)
This parameter determines whether or not the resettable totaliser will be
displayed in the auxiliary line of the display in run mode. When selected the
auxiliary display will scroll between the resettable totaliser and the totaliser
units selected.
Default = 0 (Off).
Totaliser
P820 Totaliser
Displays the current value of the, non-resettable totaliser. During run mode
this totaliser can be viewed via the “Totaliser” hot key,
. Unlike the
resettable totaliser this totaliser cannot be reset whilst in run mode, it can
however be reset whilst in program mode by accessing
P820 Totaliser
and
entering
zero
.
Содержание Ultra 3
Страница 1: ...Ultra 3 Instruction Manual...
Страница 14: ...ULTRA 3 INSTRUCTION MANUAL 14 EU Certificate of Conformity...
Страница 18: ...ULTRA 3 INSTRUCTION MANUAL 18 The full dimensions of the enclosure are as shown below...
Страница 22: ...ULTRA 3 INSTRUCTION MANUAL 22 Dimensions of the panel enclosure are as shown below...
Страница 178: ...ULTRA 3 INSTRUCTION MANUAL 178 NOTES...