![Puls Dimension C Series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/puls/dimension-c-series/dimension-c-series_manual_1624181002.webp)
CPS20.241-60
C-Series
24V,
400W,
DC/DC
C
ONVERTER
Sep. 2019 / Rev. 1.1 DS-CPS20.241-60-EN
All parameters are specified at 24.5V, 16.3A, 110Vdc, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
2/22
I
NDEX
Page
Page
Intended Use .......................................................3
Installation Requirements ...................................3
AC-Input...............................................................4
DC-Input...............................................................4
Input Inrush Current ...........................................5
Output .................................................................6
Hold-up Time .......................................................7
DC-OK Relay Contact ..........................................7
Efficiency and Power Losses................................8
Lifetime Expectancy and MTBF ...........................8
Functional Diagram .............................................9
Terminals and Wiring ..........................................9
Front Side and User Elements ........................... 10
EMC .................................................................... 11
Environment ...................................................... 12
Protection Features ........................................... 13
Safety Features .................................................. 13
Dielectric Strength ............................................ 14
Approvals and Declarations .............................. 15
RoHS, REACH and Other Fulfilled Standards .. 15
Physical Dimensions and Weight ..................... 16
Accessories ........................................................ 17
ZM2.WALL - Wall Mounting Bracket ....... 17
ZM13.SIDE - Side Mounting Bracket ........ 17
Application Notes ............................................. 18
Peak Current Capability ........................... 18
Inductive and Capacitive Loads................ 18
External Input Protection ......................... 19
Output Circuit Breakers ............................ 19
Charging of Batteries ............................... 19
Parallel Use to Increase Output Power .... 20
Parallel Use for Redundancy .................... 20
Series Operation ....................................... 21
Back-feeding Loads .................................. 21
Use in a Tightly Sealed Enclosure ............ 21
Mounting Orientations ............................ 22
The information presented in this document is believed to be accurate and reliable and may change without notice.
No part of this document may be reproduced or utilized in any form without permission in writing from the publisher.
T
ERMINOLOGY AND
A
BREVIATIONS
PE and
symbol
PE is the abbreviation for
P
rotective
E
arth and has the same meaning as the symbol
.
Earth, Ground
This document uses the term “earth” which is the same as the U.S. term “ground”.
T.b.d.
To be defined, value or description will follow later.
DC 110V
A figure displayed with the AC or DC before the value represents a nominal voltage with
standard tolerances (usually ±15%) included.
E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V)
110Vdc
A figure with the unit (Vdc) at the end is a momentary figure without any additional
tolerances included.
may
A key word indicating flexibility of choice with no implied preference.
shall
A key word indicating a mandatory requirement.
should
A key word indicating flexibility of choice with a strongly preferred implementation.