TOPCUT TIMES IN DETAIL
(ONLY FOR HL SERIES 30-50)
Global time [min]
Total duration of the TopCut cycle.
Minimum value allowed
5min
Maximum value allowed
60min
Wait time[s]
Waiting time before the introduction of the knifes into the wagon.
Minimum value allowed
30sec
Maximum value allowed
300sec
Knifes time IN[s]
Time in which the knifes are inside the wagon.
Minimum value allowed
5sec
Maximum value allowed
150sec
T.Knife OUT[s]
Time in which the knifes are out of the wagon.
Minimum value allowed
5sec
Maximum value allowed
150sec
Start TopCut
It defines from which component the TopCut system should start.
Stop TopCut
It defines from which component the system ends the TopCut
If the value is “0” the TopCut system function from the first component set until the end of the global time.
If the value set is higher than “1 the TopCut system function from the start component to the Stop component.