HL Series – Instructions manual
18
LOAD
START
Once selected the recipe press
(F6) or
to start the selected recipe load.
It will be visualized the components name, the programmed loading weight and
during the loading operation the weight will gradually decrease to 0. When the
programmed load will reach the 85% the alarm will start ringing intermittently. The
sound frequency will gradually increase as the loading program will get to its end.
Once reached the set weight, the acoustic signal will continue for about 4 seconds.
In case of manual passage, press the key
to move to next component.
Press key
to go to previous component.
In case of automatic passage of the component, the weight indicator will
automatically pass to the next component when it reaches the set weight. It
is possible to use the keys
and
to move between the different
components.
By pressing
(F5) while working, it is possible to modify the setting
AUTO - MAN passage. Press
to exit.
By pressing
(F4) it is possible to lock the displayed weight. The
locked weight will flash through an alarm. Press again
(F4) to unlock
the weight.
To rest the loading quantity, press
(F7)
Through the key
(F6) it’s displayed the total weight.
At the end of components load, it will be counted, if programmed, the final
mixing time. Once finished the alarm will ring and the weighing indicator will
exit from the loading operation and it will go back to the total weight menu. If
the time hasn’t been set, at the end of the components load, the weighing
indicator will directly go back to the total weight screen.
To interrupt the loading operation press
for 3 seconds. The weighing
indicator will ask to confirm the operation and then it will go back to total
weight menu.
If a printer is connected to the weighing indicator, at the end of the load
operation there is the data printing.
In no matter what moment of the loading process, the operator can activate
or deactivate the TopCut system with the key