![PTI security systems Falcon XT Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/pti-security-systems/falcon-xt/falcon-xt_installation-manual_1623323028.webp)
24
For Direct Ethernet connections:
1.
Using the supplied Ethernet cable, connect one end of the cable to
the bottom right corner of the Falcon XT board. If desired, a cable
of different length can be used but it must meet CAT5 or better
specifications and cannot exceed the length limit of 100 meters (328
feet).
2. If needed, run the cable through conduit to the control software
computer.
3. Connect the other end to the Ethernet port located on the back of the
computer.
For Router/Switch Ethernet connections:
1. Two Ethernet cables are required for this configuration. One is
supplied. Using the supplied Ethernet cable, connect one end of the
cable to the connector on the bottom right corner of the Falcon XT
board.
2. Connect the other end of the cable to the router.
3. Connect one end of the second cable to the software computer.
4.
Connect the other end of the cable to the router.
5.
Power-up the router.
For USB connections:
1.
The USB cable provided with the Falcon XT MUST be used for USB
connections as it contains the necessary circuit protection. Failure
to use this cable for USB connections will void the warranty on the
Falcon XT. Connect the smaller end of the USB cable to the USB
port located on the bottom middle of the Falcon XT board.
2. Run the USB cable through a knockout on the controller housing to
the control software computer.
3. Connect the larger end of the USB cable to a USB port located on
the back of the computer.
For RS232 connections:
1.
RS232 cables for connection of the FalconXT to the StorLogix
computer are available as an accessory from PTI Security Systems.
Connect the end marked ‘Controller’ to the RS232C port located on
the bottom middle of the controller circuit board.
2. If needed, run the cable through conduit to the control software
computer.
Note: Unplug the connectors from this cable to allow the cable to be
pulled through the conduit.
3.
Connect the end marked ‘PC’ to the RS232 port located on the back
of the computer.
Do NOT connect the
controller to power at
this point. Only connect power
when instructed to during the
installation steps on the following
pages.
Connecting the
controller to the
computer via Ethernet is not the
only point in the system when
CAT5 network cable can be used.
CAT5 network cable can also be
used for RS-485 communication
wiring. Refer to the Wire Needed
section in Chapter 1 for more
information on the correct wire
to use for various parts of the
installation.
Содержание Falcon XT
Страница 1: ...System Installation Manual www ptisecurity com 800 523 9504 Revised March 2016...
Страница 24: ......
Страница 42: ......
Страница 43: ...Chapter 3 Troubleshooting Troubleshooting Concepts Troubleshooting Gates...
Страница 63: ...Appendix 59...
Страница 64: ...For Technical Support Please Visit support ptisecurity com www ptisecurity com...