Keep a map of the site
showing the location of
every AI device, power supply,
system component, wire direction,
and junction box. The installer
should keep a copy of this in their
customer records for the site and
the site should also maintain a
copy along with the manuals in
a location that is safe but easily
accessible for those who might
need to maintain, service, or
troubleshoot the equipment.
Equipment Location and Site Layout
Equipment and mounting locations should be laid out and planned
in advance of installation. Use a set of site plans to lay equipment
locations and to determine the amount of conduit and wire needed.
A copy of this can be sent to your PTI Security Systems Sales
Representative so they can review it with you to make sure that
you get the equipment that you need. Be sure to discuss the local
code particular to your municipality with your Sales Representative.
Plans should be kept in a safe location after the site is complete to
help with future additions and site maintenance.
Falcon XT Location
A secure room, closet, or cabinet should be set aside for the Falcon
XT. This room often will also contain DVRs, power supplies, relay
boards, wireless multiplexers, and alarm panels. This room should
have adequate ventilation with air conditioning and be secure, but
with access for maintenance.
StorLogix Computer
The StorLogix computer is generally located at the main desk but
must have some proximity to the controller depending on cable
length and type of connection. Refer to Connecting the Controller to
the Computer for more information.
Keypads and Proximity Readers
Keypads and proximity readers are generally mounted on gooseneck
stands or bollards, or on the wall near the gate, door, or elevator that
is being accessed. Be sure to consider traffic flow, ease of access,
Americans with Disabilities Act Standards (ADA), and local code
when planning the mounting location. Gooseneck stands, bollards,
and gate operators are generally mounted on a concrete pad. Refer
to manufacturer instructions for pad size and type.
The relay that trips a gate or door should be located in a secure
area and is called a secure interior relay. For example, a gate has
an entrance keypad and an exit keypad. The gate operator should
only be connected to the exit keypad relay. When a client uses the
entrance keypad, the Falcon XT is programmed to use the exit
keypad’s relay to open the gate. This prevents anyone from breaking
into the keypad or bollard and crossing wires to open the gate.
Never install an AI
device inside a unit
that will be rented or in any
other area that is not easily
accessible for future maintenance,
expansion, or troubleshooting.
Содержание Falcon XT
Страница 1: ...System Installation Manual www ptisecurity com 800 523 9504 Revised March 2016...
Страница 24: ......
Страница 42: ......
Страница 43: ...Chapter 3 Troubleshooting Troubleshooting Concepts Troubleshooting Gates...
Страница 63: ...Appendix 59...
Страница 64: ...For Technical Support Please Visit support ptisecurity com www ptisecurity com...