12
Intercom
Wire Recommendation
(from LEF or NEM Base Station to intercoms)
PTI Part #
Belden
Wire Code
Ω per 1000’
Resistance
Description
wwir1810s *
5345FE
6.92
18 AWG, 10-conductor stranded copper
wire with overall shield and common
ground (PVC Insulation)
wwir1804s *
9418
6.92
18 AWG, 4-conductor stranded copper wire
with overall shield and common ground
(PVC Insulation)
wwir1802s
8760
6.92
18 AWG, 2-conductor stranded copper wire
with overall shield and common ground
(PVC Insulation)
wwir2210s
9946
17.5
22 AWG, 10-conductor stranded copper
wire with overall shield and common
ground (PVC Insulation)
* Denotes standard recommended wire.
Never use wire smaller than 22 AWG for installing LEF or NEM intercoms. We recommend
that 18 AWG be used in most installations for best results. Do not exceed 1600 feet in
linear distance when using 18 AWG or 600 feet in linear distance using 22 AWG.
Cameras/Video Wire Recommendations
(From DVR to Camera)
PTI Part #
Belden
Wire Code
Ω per 1000’
Resistance
Description
wwirsiamese *
549945
10.15/6.92 RG59U / 18 AWG 2-conductor in same
cable (PVC Insulation)
wwirsiamesepl
649948
10.15/6.92 RG59U / 18 AWG 2-conductor in same
cable (Plenum Insulation)
wwirrg59u
8241
10.15
Coaxial Cable with 22 AWG core and
stranded copper common ground (PVC
Insulation)
wwirrg59upl
89259
10.15
Coaxial Cable with 22 AWG core and
stranded copper common ground (Plenum
Insulation)
wwirrg59udb
8212
10.15
Coaxial Cable with 22 AWG core and
stranded copper common ground (Direct
Burial)
wwir1802s **
8760
6.92
18 AWG, 2-conductor stranded copper
wire with overall shield and common
ground (PVC Insulation)
wwir2210s ***
9946
17.5
22 AWG, 10-conductor stranded copper
wire with overall shield and common
ground (PVC Insulation)
wwir2450 ***
9585
25.67
24 AWG, 50-conductor solid copper wire
(PVC Insulation)
* Denotes standard recommended wire
** 1802S can be used for power by many types of cameras.
*** 2450 or 2210 can be used for interior video signal using Baluns (see Application Note).
Baluns are video signal
converters that allow
twisted pair cable to be used to
carry video signals up to 1200
feet. Two baluns are required
for each camera connection
(one at the camera end and
one at the DVR end). This is an
efficient way to run video signal
on sites with a lot of cameras.
Contact a PTI Security Systems
Sales Representative for more
information on Baluns.
When retrofitting an
existing facility, we do
NOT recommend that you use the
existing wiring. New wire should
be pulled and all new connections
made. Old wiring is often the
source of many problems in a
system and the initial investment
to install new wire will make the
overall retrofit experience much
better as there is less likely to be
problems in the new wiring if it is
installed correctly.
Содержание Falcon XT
Страница 1: ...System Installation Manual www ptisecurity com 800 523 9504 Revised March 2016...
Страница 24: ......
Страница 42: ......
Страница 43: ...Chapter 3 Troubleshooting Troubleshooting Concepts Troubleshooting Gates...
Страница 63: ...Appendix 59...
Страница 64: ...For Technical Support Please Visit support ptisecurity com www ptisecurity com...