10356360_V_1_1.DOC
32/32
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Please note:
This fuse is being used for both 115 V and 230 V.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Open the fuseholder on the rearpanel with a fitting screwdriver.
Step 2:
Remove the old fuse from the fuseholder.
Step 3:
Install the new fuse in the fuseholder.
Step 4:
Replace the fuseholder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
115/230 V AC, 50/60 Hz ~
Power consumption:
30 W
Inputs:
4, active, balanced
Gain range:
-40 to +15 dB
Input impedance:
10 kOhms
Frequency Response:
15 Hz - 20 kHz, ± 0,25 dB
15 Hz - 40 kHz, ± 3 dB
Outputs:
8, active, balanced with automatic correction for unbalanced loading
Output impedance:
<50 mOhms (electronically balanced)
Output gain range:
± 21 dB
Maximum output level:
+20 dBu
Frequency Response:
20 Hz - 20 kHz, ± 0,1 dB
15 Hz - 40 kHz, ± 3 dB
Distorsion:
0.001 % (1 kHz @ 18 dBu)
S/N-ratio:
115 dB
Channel separation:
< -100 dB
Filter:
Slopes:
6, 12, 18, 24 or 48 dB/Oktave
Type:
Bessel, Butterworth or Linkwitz-Riley
Crossover frequency:
20 Hz - 20 kHz
Delay:
0~0;45 s
Dimensions (WxHxD):
482 x 44 x 200 mm
Weight:
3 kg
Please note: Every information is subject to change without prior notice. 14.07.2005