background image

Front panel

Meters

PSP MasterComp’s and PSP MicroComp's meters contain VU and PPM needle readings, 
contextual numeric readings which are held for two seconds, and overload LED indicators 
that are held until reset. All main parameters of meters are rear panel controlled.

VU is mainly indicated by a long black needle and the contextually displayed number on the 
left part of the meter.

PPM is mainly indicated by a short red needle and the contextually displayed number on the 
right part of the meter. The black text turns to red one if 0dBFS or greater is detected. Please 
note that the reading is not equal to digital metering if the integration time is set to a greater 
value then 0ms.

PSP MasterComp & PSP MicroComp operation manual

7

VU held 

value

PPM held 

value

PPM 

indication

VU 

indication

Overload 

indication

Содержание Master Comp

Страница 1: ...PSP Master Comp PSP MicroComp Stereo Mastering and Mixing Compressors...

Страница 2: ...isoundMastering Victoria Australia Joachim Krukowski Jarocin Poland Hubert Pietrzykowski PSPaudioware com s c Warsaw Poland ___________________________________________________________________ PSP Mast...

Страница 3: ...d into the SOFTWARE the accompanying printed materials and any copies of the SOFTWARE are owned by PSP The SOFTWARE is protected by copyright laws and international treaty provisions Unauthorized repr...

Страница 4: ...of the demo version 6 Front panel 7 Meters 7 Controls 9 Rear Panel 14 Plugin Information Plate 14 Knobs 14 Operation 16 Working with meters 16 Rear Panel operation 16 Using meters preferences paramete...

Страница 5: ...fine blending between the processed and clean signal Optional high quality brick wall output limiter with automatic release time Advanced PPM VU meters with contextual readings and adjustable paramet...

Страница 6: ...acking In the case of PSP MasterComp the latency is considerably larger up to 37ms depending on sample rate This is because of the precise FIR finite impulse response filters used for FAT double sampl...

Страница 7: ...ck needle and the contextually displayed number on the left part of the meter PPM is mainly indicated by a short red needle and the contextually displayed number on the right part of the meter The bla...

Страница 8: ...The opposite situation may also occur when PPM integration is set to 0ms and it reads over 0dBFS in this case the LEDs do not blink at all because they are waiting for the minimum number of overloaded...

Страница 9: ...may require turning it off for a more musical result Release Sets a release time within a wide range from 0 1s to 10s in PSP MasterComp and from 0 03s to 3s in PSP MicroComp Sets the nominal release t...

Страница 10: ...ile a cut filter gives attenuation down to 15dB High s c PSP MasterComp only Controls the high cut or high shelf frequency of the side chain filter High s c type switch PSP MasterComp only Clicking th...

Страница 11: ...MasterComp only Sets the amount of linking between channels Variable control of this parameter allows you to find the most musical setting that won t shift the stereo field Link switch PSP MicroComp...

Страница 12: ...PSP MasterComp or Fast Smooth switch PSP MicroComp Engages the premium quality PSP MasterComp and high quality PSP MicroComp Smooth Level Detector algorithm In this mode compression distortion is sign...

Страница 13: ...this plug in after mixing dry with processed signal and output gain stage The ceiling level of the limiter is set to 0dBFS Stereo Mono PSP MicroComp only Engages the stereo processing mode Mono mode...

Страница 14: ...e default value is 14dBFS This value is stored as a preference setting PPM integration time The PPM integration time knob sets the attack ballistics for the PPM meters The default value is 10ms This v...

Страница 15: ...rload counter knob sets how many overloaded samples it will take to make the overload LEDs light The default value is 3 samples This value is stored as a preference setting PSP MasterComp PSP MicroCom...

Страница 16: ...are a kind of peak meters They show the level value very close to digital peak values Typically they have 10ms or 5ms attack and about 1000 2000ms release times In many cases they are more practical t...

Страница 17: ...BANK label to permanently store the default preset bank Press Command Mac or Control PC and double click to restore the factory default bank PRESET SECTION Click the green arrow icon to load a preset...

Страница 18: ...gladly answer all of your questions As a rule we respond within 24 hours PSPaudioware com s c Kwadratowa 4 19 05 509 J zefoslaw Poland ph 48 601 96 31 73 www PSPaudioware com contact PSPaudioware com...