WIL-17011-E-02
15
CSA-Certified Pumps
SECTION 7
PUMP DISASSEMBLY
Tools Required:
3/8" Box Wrench (GPS1)
1/2" Box Wrench
(GPS220/GPS230)
7/16
″
Socket Wrench (GPS1)
Two 1" Socket Wrench
(GPS220/GPS230)
Adjustable Wrench
Vise equipped with soft jaws
(such as plywood, plastic or other
suitable material)
CAUTION:
Before attempting any maintenance or repair, disconnect the compressed
air line to the pump and allow all air pressure to bleed from the pump. Disconnect all
intake, discharge, and air lines. Drain the pump by turning it upside down and allowing
any fluid to flow into a suitable container. Be aware of any hazardous effects of contact
with your process fluid.
NOTE:
Your specific pump model may vary from the configuration shown; however,
pump disassembly procedure will be the same.
NOTE:
Replace worn parts with genuine Wilden parts for reliable performance.
Step 1
Step 2
Step 3
Before starting disassembly, mark a line
from each liquid chamber to its
corresponding air chamber. This line will
assist in proper alignment during
reassembly.
Using an appropriately-sized wrench,
remove the discharge manifold from the
liquid chambers.
Inspect ball cage area of manifold for
excessive wear or damage. Remove the
discharge valve balls and valve seats
from the liquid chambers, and inspect for
nicks, gouges, chemical attack or
abrasive wear. Replace worn parts with
genuine Wilden parts for reliable
performance.
DISASSEMBLY / REASSEMBLY