background image

ALF-13131-E-02

All-Flo

27

WARRANTY. All All-Flo products shall be covered by the standard All-Flo Limited Warranty in effect at the time 

of shipment. This warranty (which may be modified by All-Flo at any time) provides:

MATERIALS SOLD ARE WARRANTED TO THE ORIGINAL USER AGAINST DEFECTS IN WORKMANSHIP OR 

MATERIALS UNDER NORMAL USE (RENTAL USE EXCLUDED) FOR FIVE YEARS AFTER PURCHASE DATE. ANY 

PUMP WHICH IS DETERMINED TO BE DEFECTIVE IN MATERIAL AND WORKMANSHIP AND RETURNED TO 

ALL-FLO, SHIPPING COSTS PREPAID, WILL BE REPAIRED OR REPLACED AT ALL-FLO’S OPTION. CUSTOMER 

SHALL NOTIFY ALL-FLO IN WRITING WITHIN 30 DAYS OF ANY CLAIMED DEFECTS. NO MATERIALS CAN BE 

RETURNED WITHOUT THE PRIOR CONSENT OF ALL-FLO, AND IF APPROVED SHALL BE RETURNED TO  

ALL-FLO FREIGHT PREPAID. ALL-FLO’S LIABILITY FOR ANY BREACH OF THIS WARRANTY SHALL BE  

LIMITED TO EITHER REPLACEMENT OF THE MATERIALS OR, AT ALL-FLO’S SOLE OPTION, THE REFUND OF 

THE PURCHASE PRICE. ALL-FLO SHALL NOT BE HELD LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL 

DAMAGES CAUSED BY BREACH OF THIS WARRANTY. THIS EXCLUSION APPLIES WHETHER SUCH DAMAGES 

WERE SOUGHT BASED ON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY 

IN TORT, OR ANY OTHER LEGAL THEORY. FURTHER, ALL-FLO SHALL NOT BE LIABLE FOR LOSSES, DELAYS, 

LABOR COSTS, OR ANY OTHER COST OR EXPENSE DIRECTLY OR INDIRECTLY ARISING FROM THE USE OF 

MATERIALS. ALL-FLO’S LIABILITY IS EXPRESSLY LIMITED TO THE REPLACEMENT OR REPAIR OF DEFECTIVE 

GOODS, OR THE TOTAL VALUE OF SUCH GOODS. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, 

WHETHER EXPRESS, IMPLIED, OR ORAL INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY, ANY 

IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES  

OTHERWISE ARISING FROM A COURSE OF DEALING OR TRADE. All-Flo will not, in ANY event, be liable for any 

loss of profit, interruption of business or any other special, consequential or incidental damages suffered or 

sustained by Customer. All-Flo’s total maximum liability to the customer in respect of sale of materials or  

services rendered by All-Flo is limited to the total monies received by All-Flo from the customer for the  

particular materials described in Customer’s order.

All-Flo does not warrant any part or component that it does not manufacture, but will assign to the original 

end-user purchaser of any warranty received by it from the manufacturer, to extent such pass through is  

permitted by the manufacturer.

REGISTRATION FORM

Pump Model  _________________________________   Pump Serial Number  __________________________

Company Name  _____________________________________________________________________________

Name  ______________________________________ Email 

 _______________________________________

Phone #  ____________________________  City _____________________  State  ______ Zip  ___________

Qty of Pumps  ________________________________  Fluid Pumping  _______________________________

How did you hear about us? Existing All-Flo user,  

Web, Distributor, Magazine…

______________________________________________________

www.all-flo.com/registration-form.html 

WARRANTY AND REGISTRATION

Scan QR code and 

complete form  

on mobile phone  

or visit

MAIL TO:

 

All-Flo | Attn: Product Registration

22069 Van Buren Street, Grand Terrace, CA 92313-5651

SECTION

10

Содержание All-Flo S050

Страница 1: ...IOM INSTALLATION OPERATION MAINTENANCE S050 METAL 1 2 INCH AIR OPERATED DOUBLE DIAPHRAGM PUMP...

Страница 2: ...R DIAPHRAGMS 9 TPE DIAPHRAGMS 9 PTFE DIAPHRAGMS 9 SECTION 6 INSTALLATION TROUBLESHOOTING AND MAINTENANCE INSTALLATION 10 11 TROUBLESHOOTING 12 OPERATION 13 MAINTENANCE 13 SECTION 7 REPAIR AND ASSEMBLY...

Страница 3: ...32 F to 180 F 0 C to 82 C PVDF 0 F to 250 F 18 C to 121 C Nylon 0 F to 200 F 18 C to 93 C Temperature limits are solely based upon mechanical stress and certain chemicals will reduce the maximum opera...

Страница 4: ...Muffler 8 Stainless Steel Hardware Metal Muffler B PTFE Coated Stainless Steel Hardware Plastic Muffler C PTFE Coated Stainless Steel Hardware Metal Muffler D Zinc Plated Steel Hardware Plastic Muffle...

Страница 5: ...m Discharge Left P Suction Right Discharge Center Front Q Suction Right Discharge Center Rear U Suction Left Discharge Center Front V Suction Left Discharge Center Rear 1 Dual Suction Single Discharge...

Страница 6: ...eft diaphragm causing the left diaphragm to move outward to the left Since both the left diaphragm and the right diaphragm are connected via a diaphragm rod when the left diaphragm moves to the left t...

Страница 7: ...default ports See part number matrix option code for additional porting options 10 3 262mm 1 8 46mm 6 7 170mm 9 5 241mm 11 2 284mm 5 4 137mm 4 4 112mm 3 6 91mm 4 0 102mm 0 3 8mm 3 2 81mm 1 1 28mm 6 4...

Страница 8: ...3 261 62mm 1 8 46mm 6 3 160mm 9 5 241mm 11 2 284mm 7 3 185mm 6 3 160mm 0 3 8mm 1 MNPT OR 1 MBSP x4 1 2 FNPT or FBSP 3 8 18 FNPT Exhaust Port 1 4 18 FNPT Air Inlet 3 6 91mm 4 0 102mm 5 4 137mm 4 4 112...

Страница 9: ...nlet 1 4 FNPT Liquid Inlet FNPT BSP Liquid Outlet FNPT BSP Height 11 2 284 mm Width 10 3 262 mm Depth 6 4 163 mm Performance Specifications Max Flow 9 gpm 34 1 lpm Max Air Pressure 120 psi 8 3 bar Max...

Страница 10: ...tion it is recommended to pipe the exhaust air above the liquid source In the event of a diaphragm failure this will reduce or eliminate the possibility of liquid discharging through the exhaust onto...

Страница 11: ...ALF 13131 E 02 All Flo 11 SUGGESTED INSTALLATION This illustration is a generic representation of an air operated double diaphragm pump...

Страница 12: ...Suction valve closed Suction line plugged No liquid in the suction tank Suction lift excessive Debris stuck in valves Excessive wear of check valves Air leak on suction side with suction lift Pump Cy...

Страница 13: ...suction valve restrict the suction line and may cause damage to the diaphragms Suction strainers may be employed to reduce or eliminate larger solids but routine maintenance is necessary in order to...

Страница 14: ...closed and disconnected While wearing personal protective equip ment flush drain and process liquid from the pump in a safe manner WARNING Maintenance must not be performed when a hazardous atmo spher...

Страница 15: ...Plate and Flat Washer 1 4 from one side of the pump STEP 10 Placing the inch wrench on the remaining Outer Diaphragm Plate and the 7 16 inch wrench on the Diaphragm Rod Assembly remove the remaining...

Страница 16: ...d process liquid from the pump in a safe manner WARNING Maintenance must not be performed when a hazardous atmo sphere is present WARNING For pump models with non metallic manifolds air valves or cham...

Страница 17: ...disassembly During assembly ensure that the open side of the lip seals are both facing each other inward Install the shuttle plate with the smooth shinny side toward the shuttle car Lubrication of the...

Страница 18: ...are closed and disconnected While wearing personal protective equip ment flush drain and process liquid from the pump in a safe manner WARNING Maintenance must not be performed when a hazardous atmo s...

Страница 19: ...mble the pilot valve reverse the order of disassembly Should process fluid have contact with the pilot valve O rings they should be replaced as swelling may occur and cause irregular operation During...

Страница 20: ...ALF 13131 E 02 All Flo 20 ALUMINUM AND STAINLESS STEEL PUMPS WITH ALUMINUM CENTER SECTION S050 A SECTION 8 EXPLODED VIEW PARTS LIST...

Страница 21: ...SLEEVE 2 ALL MODELS 10204 40 Polyproplyene 130 O RING END SPACER 2 ALL MODELS 11923 11 Nitrile 140 LIP SEAL DIAPHRAGM ROD 2 ALL MODELS 12000 76 Nitrile 150 RETAINING PLATE 2 ALL MODELS 12708 54 Nylon...

Страница 22: ...ANGE NUT 5 16 18 16 S050 A 12608 25 Plated Steel S050 3 12608 26 Stainless Steel 371 LOCK WASHER 1 4 4 S050 A 12350 25 Plated Steel S050 3 12350 26 Stainless Steel 372 WASHER SPLIT LOCK 5 16 16 S050 A...

Страница 23: ...ALF 13131 E 02 All Flo 23 ALUMINUM AND STAINLESS STEEL PUMPS WITH PLASTIC CENTER SECTION S050 P EXPLODED VIEW PARTS LIST...

Страница 24: ...40 Polyproplyene 130 O RING END SPACER 2 ALL MODELS 11923 11 Nitrile 140 LIP SEAL DIAPHRAGM ROD 2 ALL MODELS 12000 76 Nitrile 150 RETAINING PLATE 2 ALL MODELS 12708 54 Nylon 160 N A 170 INNER DIAPHRAG...

Страница 25: ...el 361 HEX NUT 1 4 20 4 S050 PA 12600 25 Plated Steel S050 P3 12600 26 Stainless Steel 362 HEX FLANGE NUT 5 16 18 16 S050 PA 12608 25 Plated Steel S050 P3 12608 26 Stainless Steel 371 LOCK WASHER 1 4...

Страница 26: ...ture range 10 F to 180 F 12 C to 82 C EPDM is a general purpose elastomer with good resistance to many acids and bases Temperature range 40 F to 280 F 40 C to 138 C SANTOPRENE is an injection molded m...

Страница 27: ...TIES WHETHER EXPRESS IMPLIED OR ORAL INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM A COUR...

Страница 28: ...esigning and manufacturing the highest quality product available to industry Since the beginning in 1986 All Flo engineers have used their extensive knowledge of today s engineered materials advanced...