background image

ALF-13131-E-02

All-Flo

12

TROUBLESHOOTING

PROBLEM EFFECT/SOLUTION

Pump Will Not Cycle 

 

Discharge line closed or plugged

 

Discharge filter blocked

 

Check valve stuck

 

Air filter blocked

 

Air supply valve closed

 

Air supply hooked up to muffler side of pump

 

Compressor not producing air or turned off

 

Muffler iced or blinded

 

Diaphragm ruptured

 

Plant air supply line ruptured

 

Air valve wear/debris

 

Pilot sleeve wear/debris

 

Diaphragm rod broken

 

Diaphragm plate loose

Pumped Fluid Coming Out of Muffler 

 

Diaphragm ruptured

 

Diaphragm plate loose

 

Inlet liquid pressure excessive (above 10 psig) 

Pump Cycles but no Flow 

 

Inlet strainer clogged

 

Suction valve closed

 

Suction line plugged

 

No liquid in the suction tank

 

Suction lift excessive

 

Debris stuck in valves

 

Excessive wear of check valves

 

Air leak on suction side with suction lift

Pump Cycles with Closed Discharge Valve 

 

Debris stuck in check valve

 

Excessive wear of check valves

Pump Running Slowly/Not Steady 

 

Air compressor undersized 

 

Leak in air supply

 

Air-line, filter regulator or needle valve undersized

 

Muffler partially iced or blinded

 

Air valve gasket leak or misalignment

 

Air valve wear/debris

 

Pilot sleeve wear/debris

 

Liquid fluid filter blocked

 

Pump may be cavitating, reduce speed of operation

 

Suction strainer clogged

Pump Will Not Prime 

 

Air leak in suction pipe

 

Air leak in pump manifold connections

 

Suction strainer and lines clogged

 

Excessive lift conditions

 

Check valve wear

 

Debris in check valve

Содержание All-Flo S050

Страница 1: ...IOM INSTALLATION OPERATION MAINTENANCE S050 METAL 1 2 INCH AIR OPERATED DOUBLE DIAPHRAGM PUMP...

Страница 2: ...R DIAPHRAGMS 9 TPE DIAPHRAGMS 9 PTFE DIAPHRAGMS 9 SECTION 6 INSTALLATION TROUBLESHOOTING AND MAINTENANCE INSTALLATION 10 11 TROUBLESHOOTING 12 OPERATION 13 MAINTENANCE 13 SECTION 7 REPAIR AND ASSEMBLY...

Страница 3: ...32 F to 180 F 0 C to 82 C PVDF 0 F to 250 F 18 C to 121 C Nylon 0 F to 200 F 18 C to 93 C Temperature limits are solely based upon mechanical stress and certain chemicals will reduce the maximum opera...

Страница 4: ...Muffler 8 Stainless Steel Hardware Metal Muffler B PTFE Coated Stainless Steel Hardware Plastic Muffler C PTFE Coated Stainless Steel Hardware Metal Muffler D Zinc Plated Steel Hardware Plastic Muffle...

Страница 5: ...m Discharge Left P Suction Right Discharge Center Front Q Suction Right Discharge Center Rear U Suction Left Discharge Center Front V Suction Left Discharge Center Rear 1 Dual Suction Single Discharge...

Страница 6: ...eft diaphragm causing the left diaphragm to move outward to the left Since both the left diaphragm and the right diaphragm are connected via a diaphragm rod when the left diaphragm moves to the left t...

Страница 7: ...default ports See part number matrix option code for additional porting options 10 3 262mm 1 8 46mm 6 7 170mm 9 5 241mm 11 2 284mm 5 4 137mm 4 4 112mm 3 6 91mm 4 0 102mm 0 3 8mm 3 2 81mm 1 1 28mm 6 4...

Страница 8: ...3 261 62mm 1 8 46mm 6 3 160mm 9 5 241mm 11 2 284mm 7 3 185mm 6 3 160mm 0 3 8mm 1 MNPT OR 1 MBSP x4 1 2 FNPT or FBSP 3 8 18 FNPT Exhaust Port 1 4 18 FNPT Air Inlet 3 6 91mm 4 0 102mm 5 4 137mm 4 4 112...

Страница 9: ...nlet 1 4 FNPT Liquid Inlet FNPT BSP Liquid Outlet FNPT BSP Height 11 2 284 mm Width 10 3 262 mm Depth 6 4 163 mm Performance Specifications Max Flow 9 gpm 34 1 lpm Max Air Pressure 120 psi 8 3 bar Max...

Страница 10: ...tion it is recommended to pipe the exhaust air above the liquid source In the event of a diaphragm failure this will reduce or eliminate the possibility of liquid discharging through the exhaust onto...

Страница 11: ...ALF 13131 E 02 All Flo 11 SUGGESTED INSTALLATION This illustration is a generic representation of an air operated double diaphragm pump...

Страница 12: ...Suction valve closed Suction line plugged No liquid in the suction tank Suction lift excessive Debris stuck in valves Excessive wear of check valves Air leak on suction side with suction lift Pump Cy...

Страница 13: ...suction valve restrict the suction line and may cause damage to the diaphragms Suction strainers may be employed to reduce or eliminate larger solids but routine maintenance is necessary in order to...

Страница 14: ...closed and disconnected While wearing personal protective equip ment flush drain and process liquid from the pump in a safe manner WARNING Maintenance must not be performed when a hazardous atmo spher...

Страница 15: ...Plate and Flat Washer 1 4 from one side of the pump STEP 10 Placing the inch wrench on the remaining Outer Diaphragm Plate and the 7 16 inch wrench on the Diaphragm Rod Assembly remove the remaining...

Страница 16: ...d process liquid from the pump in a safe manner WARNING Maintenance must not be performed when a hazardous atmo sphere is present WARNING For pump models with non metallic manifolds air valves or cham...

Страница 17: ...disassembly During assembly ensure that the open side of the lip seals are both facing each other inward Install the shuttle plate with the smooth shinny side toward the shuttle car Lubrication of the...

Страница 18: ...are closed and disconnected While wearing personal protective equip ment flush drain and process liquid from the pump in a safe manner WARNING Maintenance must not be performed when a hazardous atmo s...

Страница 19: ...mble the pilot valve reverse the order of disassembly Should process fluid have contact with the pilot valve O rings they should be replaced as swelling may occur and cause irregular operation During...

Страница 20: ...ALF 13131 E 02 All Flo 20 ALUMINUM AND STAINLESS STEEL PUMPS WITH ALUMINUM CENTER SECTION S050 A SECTION 8 EXPLODED VIEW PARTS LIST...

Страница 21: ...SLEEVE 2 ALL MODELS 10204 40 Polyproplyene 130 O RING END SPACER 2 ALL MODELS 11923 11 Nitrile 140 LIP SEAL DIAPHRAGM ROD 2 ALL MODELS 12000 76 Nitrile 150 RETAINING PLATE 2 ALL MODELS 12708 54 Nylon...

Страница 22: ...ANGE NUT 5 16 18 16 S050 A 12608 25 Plated Steel S050 3 12608 26 Stainless Steel 371 LOCK WASHER 1 4 4 S050 A 12350 25 Plated Steel S050 3 12350 26 Stainless Steel 372 WASHER SPLIT LOCK 5 16 16 S050 A...

Страница 23: ...ALF 13131 E 02 All Flo 23 ALUMINUM AND STAINLESS STEEL PUMPS WITH PLASTIC CENTER SECTION S050 P EXPLODED VIEW PARTS LIST...

Страница 24: ...40 Polyproplyene 130 O RING END SPACER 2 ALL MODELS 11923 11 Nitrile 140 LIP SEAL DIAPHRAGM ROD 2 ALL MODELS 12000 76 Nitrile 150 RETAINING PLATE 2 ALL MODELS 12708 54 Nylon 160 N A 170 INNER DIAPHRAG...

Страница 25: ...el 361 HEX NUT 1 4 20 4 S050 PA 12600 25 Plated Steel S050 P3 12600 26 Stainless Steel 362 HEX FLANGE NUT 5 16 18 16 S050 PA 12608 25 Plated Steel S050 P3 12608 26 Stainless Steel 371 LOCK WASHER 1 4...

Страница 26: ...ture range 10 F to 180 F 12 C to 82 C EPDM is a general purpose elastomer with good resistance to many acids and bases Temperature range 40 F to 280 F 40 C to 138 C SANTOPRENE is an injection molded m...

Страница 27: ...TIES WHETHER EXPRESS IMPLIED OR ORAL INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM A COUR...

Страница 28: ...esigning and manufacturing the highest quality product available to industry Since the beginning in 1986 All Flo engineers have used their extensive knowledge of today s engineered materials advanced...

Отзывы: