4
121
100
Dimensions in mm
Installation height
Pin allocation, accelerometer
GND (-)
A
Signal (+)
B
VIB 6.195
22
M8
VIB 5.740-X
VIB 5.741-X
VIB 6.195
Apply adhesive
• Prepare the adhesive for use.
• Apply the adhesive with a wooden spatula
evenly to the base of the mounting adapter and
the bonding location (approx. 1 mm thick,
C
).
Affix mounting adapter
• Press the adapter gently against the bonding lo-
cation and turn it to evenly distribute the adhe-
sive. If applicable, screw in the centering pin (
D
).
• Do not remove excess adhesive. If necessary,
apply additional adhesive around the bonding
location for greater stability.
Note
An adhesive tape may be used to hold the adapter
in place during the first hour of hardening.
Mount sensor
• Clean the contact surfaces of the sensor and the
adapter with solvent.
• Allow contact surfaces to dry.
• Thinly apply LOCTITE 243 to improve signal
transmission.
• Screw in the sensor and tighten with a torque
wrench (3 Nm).