Electrical connection

Only electricians are allowed to install accelerom-
eters. Comply with the national and international 
regulations for the installation of electrical equip-
ment. 

For the electrical connection to a 

stationary

 

condition monitoring system (CMS), the following 
connection cables are suitable.

For accelerometer 

VIB 6.195

:

 

– Sensor cable with silicon coating and straight 

cable connector, X meters long, 

VIB 5.740-X

 

 

– Sensor cable with silicon coating and angled ca-

ble connector, X meters long, 

VIB 5.741-X

 

– Sensor cable with PUR coating and straight ca-

ble connector, stainless steel, X meters long, 

VIB 5.746-L

 

 

– Sensor cable with PUR coating and angled cable 

connector, X meters long, 

VIB 5.745-L

Please find the technical data of the cables in 
the sensor and cable catalogue, which you can 
download from the PRUFTECHNIK website (www.
pruftechnik.com). 

Pin allocation, cable

Lay the cable

• Lay the cable in a cable conduit or a protective 

tube.

• Use Velcro strips or cable ties for mounting.
• Do not lay the connection cable parallel to pow-

er lines. Keep a minimum distance (> 1m).

• Lay a cable loop with sufficient excess cord at 

each connection or before each gland. 

• Label the cable ends to avoid confusion.
• Observe the terminal assignments on the CMS 

(see CMS installation manual).

Extend the cable

• Observe the maximum cable lengths (see CMS 

installation manual).

• Use shielded, 2-wire electrical cables for exten-

sion.

• Connect the cable ends in a junction box.
• Mount a metal junction box electrically insulat-

ed.

EMC protection

• Use double-shielded triaxial cables in environ-

ments exposed to strong electromagnetic radi-
ation.

• Keep the accelerometer connection cable as 

short as possible.

• Connect the triaxial cable and the accelerome-

ter connection cable in a junction box.

• Mount the junction box close to the accelerom-

eter. 

CABLE

VIB 5.740-X
VIB 5.741-X

VIB 5.745-L
VIB 5.746-L

Pin 

A

B

A

B

Color code

BN 

BU 

WT 

BN

BN: brown / BU: blue / WT: white / BK: black

Содержание VIB 6.195

Страница 1: ...Accelerometer Wind VIB 6 195 Installation and Operation ...

Страница 2: ...and Maintenance The operation of the accelerometer is mainte nance free A repair is not possible Disposal Dispose of the accelerometer after use in accor dance with applicable national regulations Mounting The frequency response and dynamic range of an accelerometer can be greatly influenced by the installation Poor coupling to the measurement location can adversely affect the signal and restrict ...

Страница 3: ...equired tools and resources Hand held drill and drill bit 3 5 mm Angle grinder and rasp Compressed air for cleaning out the hole Torque wrench with 22 mm 7 8 hex socket Solvent for degreasing Threadlocker LOCTITE 243 2 Component adhesive WEICON HB 300 Note Switch off the machine and secure it against a restart Do not switch on the machine until the adhesive has hardened approx 24 hours Select the ...

Страница 4: ...o cation and turn it to evenly distribute the adhe sive If applicable screw in the centering pin D Do not remove excess adhesive If necessary apply additional adhesive around the bonding location for greater stability Note An adhesive tape may be used to hold the adapter in place during the first hour of hardening Mount sensor Clean the contact surfaces of the sensor and the adapter with solvent A...

Страница 5: ...7 18 VDC Noise 0 1 Hz 20 kHz 0 002 ms 2 as of 2 Hz Output impedance 10 Ohm Environment Degree of protection IP 67 w cable connected Shock resistance 50 kms 2 5000 g Temperature range 30 C 80 C 22 F 176 F Temperature sensitivity 0 01ms 2 K Transverse sensitivity 5 Magnetic sensitivity 1ms 2 T at 50 Hz Base strain sensitivity 0 1ms 2 µm m Mechanical Case material Stainless steel VA 1 4305 Connector ...

Страница 6: ... cable Lay the cable Lay the cable in a cable conduit or a protective tube Use Velcro strips or cable ties for mounting Do not lay the connection cable parallel to pow er lines Keep a minimum distance 1m Lay a cable loop with sufficient excess cord at each connection or before each gland Label the cable ends to avoid confusion Observe the terminal assignments on the CMS see CMS installation manual...

Страница 7: ...5 449 CLD VIB 5 436 VIB 311221 10 TNC VIB 5 449 CLD VIBSCANNER VIBXPERT II VIBGUARD portable VIB 5 444 5 Mini Snap Extension cable optional Cable adapter Connection options for accelerometer VIB 6 195 to portable measurement devices ...

Страница 8: ...PRÜFTECHNIK 85737 Ismaning Germany www pruftechnik com LIT 61 201 EN 08 2018 Productive maintenance technology ...

Отзывы: