Accelerometers of the VIB 6.195 series are used 
for the measurement of absolute casing vibrations 
on machinery with rotating components. Due to 
the very low limit frequency, the accelerometers 
are particularly suitable for very slowly rotating 
components (n > 6 rpm) such as the main bear-
ings of a wind turbine.
The accelerometers have a current linedrive out-
put (CLD).

Safety Information

• Read these operating instructions carefully and 

store them.

• Observe the operating instructions of the con-

nected devices.

• Read and observe the safety information in 

these operating instructions!

• Only use the accelerometer as intended and for 

the permitted purpose of application.

• Use original accessories only.
• Replace defective accelerometers and cables.
• Installation by qualified personnel only.
• Comply with the applicable safety regulations 

when performing installation work on running 
machines.

• Comply with the applicable safety regulations 

when laying cables.

• Observe the technical data and the allowed 

operating conditions. In case of doubt, consult 
with PRUFTECHNIK.

• The accelerometer is in compliance with Eu-

ropean Directive 2004/108/EC. The complete 
Declaration of Conformity is available at www.
pruftechnik.com.

Repair and Maintenance

The operation of the accelerometer is mainte-
nance-free. A repair is not possible.

Disposal

Dispose of the accelerometer after use in accor-
dance with applicable national regulations.

Mounting

The frequency response and dynamic range of an 
accelerometer can be greatly influenced by the 
installation. Poor coupling to the measurement 
location can adversely affect the signal and restrict 
the frequency range. In principle, the accelerome-
ter needs a non-positive, resonance-free and rigid 
fastening to the measurement location, especially 
for measurements with high frequencies.

The most secure and stable coupling is provided 
by a screwed mounting, for which a M8 thread-
ed pin is attached to the accelerometer base by 
default. For this accelerometer series, depending 
on the requirements on site, various mounting 
adapters are available as an accessory.

Mounting adapters

 

– Screw adapter M8-90°, VIB 3.437 

(h*= 4)

 

– Screw adapter M5-flat, VIB 3.439 

(h*= 1)

 

– Bonded adapter, VIB 3.433 (h*= 8)

 

– Magnetic holder, VIB 3.423 (h*= 10)

* h: Installation height in mm, only adapter

Accelerometer / Screw adapter

Required tools and resources

 

– Hand-held drill

 

– Drill bits with depth gauge (4.2 mm /6.8 mm)

 

– Thread tap (M8/M5)

 

– 90°-countersink (for VIB 3.437)

 

– Torque wrench, SW22

 

– Compressed air for cleaning out the hole

 

– Solvent for degreasing

 

– Threadlocker (e.g., LOCTITE 243)

• Drill the mounting hole and cut the thread.

Thread hole for screw adapter VIB 3.437

Содержание VIB 6.195

Страница 1: ...Accelerometer Wind VIB 6 195 Installation and Operation ...

Страница 2: ...and Maintenance The operation of the accelerometer is mainte nance free A repair is not possible Disposal Dispose of the accelerometer after use in accor dance with applicable national regulations Mounting The frequency response and dynamic range of an accelerometer can be greatly influenced by the installation Poor coupling to the measurement location can adversely affect the signal and restrict ...

Страница 3: ...equired tools and resources Hand held drill and drill bit 3 5 mm Angle grinder and rasp Compressed air for cleaning out the hole Torque wrench with 22 mm 7 8 hex socket Solvent for degreasing Threadlocker LOCTITE 243 2 Component adhesive WEICON HB 300 Note Switch off the machine and secure it against a restart Do not switch on the machine until the adhesive has hardened approx 24 hours Select the ...

Страница 4: ...o cation and turn it to evenly distribute the adhe sive If applicable screw in the centering pin D Do not remove excess adhesive If necessary apply additional adhesive around the bonding location for greater stability Note An adhesive tape may be used to hold the adapter in place during the first hour of hardening Mount sensor Clean the contact surfaces of the sensor and the adapter with solvent A...

Страница 5: ...7 18 VDC Noise 0 1 Hz 20 kHz 0 002 ms 2 as of 2 Hz Output impedance 10 Ohm Environment Degree of protection IP 67 w cable connected Shock resistance 50 kms 2 5000 g Temperature range 30 C 80 C 22 F 176 F Temperature sensitivity 0 01ms 2 K Transverse sensitivity 5 Magnetic sensitivity 1ms 2 T at 50 Hz Base strain sensitivity 0 1ms 2 µm m Mechanical Case material Stainless steel VA 1 4305 Connector ...

Страница 6: ... cable Lay the cable Lay the cable in a cable conduit or a protective tube Use Velcro strips or cable ties for mounting Do not lay the connection cable parallel to pow er lines Keep a minimum distance 1m Lay a cable loop with sufficient excess cord at each connection or before each gland Label the cable ends to avoid confusion Observe the terminal assignments on the CMS see CMS installation manual...

Страница 7: ...5 449 CLD VIB 5 436 VIB 311221 10 TNC VIB 5 449 CLD VIBSCANNER VIBXPERT II VIBGUARD portable VIB 5 444 5 Mini Snap Extension cable optional Cable adapter Connection options for accelerometer VIB 6 195 to portable measurement devices ...

Страница 8: ...PRÜFTECHNIK 85737 Ismaning Germany www pruftechnik com LIT 61 201 EN 08 2018 Productive maintenance technology ...

Отзывы: