background image

16

CSS 12

Section 7 

 

 

 

 

 

 

 

    

Warranty Information

The Following Invalidates the Warranty:

 

 

1.  Incorrect installation 

 

 

2.  Misuse or abuse   

 

 

3.  Failure to inspect the cell on a regular basis                                

 

 

4.  Cell is used for any other purpose than 

 

 

 

described herein.

 

 

5.  Operating the Cell at a pressures exceeding 30 psig

6.  Operating the cell at salt levels lower or higher than recommended 

7.  Failure to winterize system

PROZONE

®

 Advanced Oxidation Purification Products

LIMITED WARRANTY

Warranty is offered on this unit for a period of 24 months from date of purchase, and extends only to the original purchaser.  If this unit becomes 

unserviceable due to defects in materials or workmanship within 24 months from date of purchase, it will be repaired or replaced without charge. 

Warranty does not apply to breakage due to obvious misuse.  Warranty period for a repaired or replaced unit applies to the original date of purchase 

of the unit. Manufacturer will repair or replace based on evaluation of returned unit.

In order to receive warranty service, a Returned Goods Authorization (RGA) number must be obtained from Prozone before returning the product.  

The RGA number must be issued prior to end of warranty period.   Product must be returned within 30 days of issuance of the RGA number.   If the 

product is not received by Prozone within 30 days of RGA number issuance, another RGA number must be obtained; RGA number must be obtained 

before warranty period expires. Manufacturer will replace or repair after evaluation of unit. 

This warranty along with the sales receipt must accompany the unit when it is returned.  The RGA number must be printed prominently on the bottom 

left corner of the address side of the return packaging.  To obtain an RGA number, or for any questions regarding warranty service, please contact:

 

PROZONE WATER PRODUCTS

 

Tel: 

(256) 539-4570

               3004 11th Ave.

 

Huntsville, AL 35805 

 

Fax: 

(256) 539-4225                       

 

 

 

email:  [email protected]

This warranty is void if the unit has been opened, or if the product identification label has been removed or altered.  This warranty does not cover 

damage resulting from misuse, abuse, accident, fire, flood, lightning or other acts of nature, lack of reasonable care, or subjecting the product to any 

but the specified voltage.

Under the terms of the warranty, manufacturer assumes no responsibility for any injury, loss or damage (direct, indirect, or consequential) arising out 

of the use of or inability to use the product.  Manufacturer assumes no responsibility for labor involved in removal of defective part, shipping or instal-

lation of new part. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  This warranty is in 

lieu of all other warranties, express or implied.

RETURNS WITHOUT AN RGA NUMBER WILL BE REJECTED.

Содержание CSS 12

Страница 1: ...ors Produces Crystal Clear Water Copyright 2007 202063 CSS 12 Ozone Salt Chlorinator Prozone has combined ozone and salt together in one Complete Sanitation System for your pool Prozone Water Products...

Страница 2: ...f GFCI protected circuits If installation is completed by a licensed electrician or pool equipment installer they will be required to verify this requirement for your area and comply during installati...

Страница 3: ...ify Contents 2 3 Quick Start Installation Guide 2 4 Saddle Clamp Installation Guide 2 5 Installation For New Pools 2 6 Connecting The Bypass Hoses 2 7 Alternate Installation Methods 2 8 Standard Bypas...

Страница 4: ...on the Web www prozoneint com Manufactured by Prozone Water Products 3004 11th Ave Huntsville AL 35805 CSS 12 Installer Date of Installation Control Box Control Box Model Number CSS 12 Serial Number...

Страница 5: ...r many years to come 1 3 Customer Responsibilities Record the Following Information at Initial Installation of your CSS 12 Unit Proper Water Chemistry is Important to Protect Your Valuable Investment...

Страница 6: ...chnology which produce nitrous acid compounds and other harmful byproducts Ozone is a molecule of oxygen that is formed when three atoms of oxygen are bound together instead of the normal two atoms Th...

Страница 7: ...tion 2 Product Installation Section 1 Product Information Z43 Installation Kit For new pool installation Refer to this list when ordering replacement parts Description Part Number Quantity Strainer 20...

Страница 8: ...d with the chlorine and ozone generators connected Do not add salt to the pool for at least 2 weeks allow your pool surface to completely cure and harden You may turn on your Control Box and allow wat...

Страница 9: ...bypass Exit after Filter Heater Using 2 pipe Assemble PVC Pipe with fitting Saddle Clamp Top Bottom Bushing Note direction Screws 2 Nuts 2 Figure 4 Turn pool pump OFF Locate section of existing plumb...

Страница 10: ...er strainer should be at the bottom as shown in figure 5 Locate the 3 4 MNPT by 3 4 MHT fitting Apply teflon tape to the threads of the 3 4 MNPT Screw this fitting into the second 2 tee after the filt...

Страница 11: ...11 CSS 12 Section 2 Product Installation 2 8 Standard Bypass Installation...

Страница 12: ...ool before calculating the salt requirement particularly if a salt chlorine generator has been used or sodium chloride has been previously added to the pool water It is best to use an electronic measu...

Страница 13: ...duce chlorine and effectively inject ozone in to the water the circulation system must operate at optimum levels Poor water ow or short operating cycles will hamper the ability of the CSS 12 to work p...

Страница 14: ...nough for this Water should be tested every week to maintain maximum water quality and enjoyment Salt chlorine generators may naturally increase the pH of the spa Monitor pH regularly and adjust if it...

Страница 15: ...es before freezing occurs SPRING START UP Balance your pool and perform start up as listed in this manual Section 5 Chlorine Cell Function Maintenance Section 6 Winterization and Spring Start UP Turn...

Страница 16: ...ed by Prozone within 30 days of RGA number issuance another RGA number must be obtained RGA number must be obtained before warranty period expires Manufacturer will replace or repair after evaluation...

Страница 17: ...E WATER PRODUCTS INC 3004 11TH AVE HUNTSVILLE AL 35805 Failure to return this warranty information will void this warranty Date of purchase Purchased from Model Number Supplier Telephone No Date of in...

Страница 18: ...must be restarted by turning off the power swtich located on the bottom of the unit and turning it back on again If system shuts down due to excessive salt a water sample should be taken to your pool...