Displaying and changing the values in the menus
17
Menu item
Description
Waiting time (alternating
mode)
Here you can define for how long the hot water processing must
remain in waiting mode.
Time window 1–3
Mo–Fr
Here you can select the week-days on which you want the
programmed time window to be active.
In this example the days selected are: Mo, Tu, We, Th, Fr.
06:00–22:00
Here you can select the start and stop times for the time window.
In this example the times are: Start: 06:00, Stop: 22:00
Chimney sweep
Menu item
Description
Function
Switch the "Chimney sweep" function on or off
The night heating mode will be started and the heating pumps will
be activated. The mixers move to position "Open".
Runtime
Here you can set the runtime for the "Chimney sweep" function.
When this time has elapsed, the system will switch automatically to
the previously selected operating mode.
MFC 1-6
Different menu points can be displayed in this menu depending on the functions
selected for the multi-function controller.
Menu item
Description
Target temp
Switch-on temperature
Hysteresis
Temperature range
Waiting time
Duration of waiting time for the "Cascade" function
Tmax sink
Maximum temperature of the sink for the "Temperaturedifference
controller" and “Wood-fired boiler” functions
Diff. controller max
Switch-on difference for the "Temperature difference controller"
function
Tmin source
Minimum temperature of the source for the "Temperature
difference controller" and “Wood-fired boiler” functions
Diff. controller min
Switch-off difference for the "Temperaturedifference controller"
function