Set the different fields in this way:
•
Inputs: Etheret
•
Server IP: Write the control network IP for the Barco projector. For
this example 10.0.12.139.
•
Port Number: 43748. It’s mandatory tu use this port for the Alchemy.
•
Input x: Write the ASCII command you want to send to the Alchemy
server every time the associated input becomes active. It’s mandatory
that the messages matches with the ones from the
Apendix I
table.
•
Input Message Terminator: It’s possible to choose any of the four mes-
sage terminators, but is recommended to use the “blank” one.
In the
Figure 8.4.4A
example, every time become activated the:
•
Input 1: The PAA20+ will send a message to the Alchemy to start the
playing of the player loaded content.
•
Input 2: The PAA20+ will send a message to the Alchemy to pause the
current playback.
•
Input 3: The PAA20+ will send a message to the Alchemy to stop the
current playback.
•
Input 4: The PAA20+ will send a message to the Alchemy to activate
the Emergency State with it’s related actions.
Emergency Stop
special case:
The Emergency Stop action definition is this: “Sets an error, forces the
manual mode, stops the player and triggers automation events associated
with Emergeny Stop”.
This Emergency Stop could be used when you have a Fire or Emergency trig-
ger in the theatre. It’s a good practise to follow these steps:
•
Connect the Fire or Emergency line from the Alarm system to one of
the Inputs of the PAA20+, in the
Figure 8.4.4A
example we have
used the “Input 4”.
•
Set the Input, Server IP, Port Number and Input Message terminator
as explained. Click on it’s “Save” button every time you change the
seeting.
INSTALLATION MANUAL: PAA20+ V 2.0 (10/2021)
88
Содержание PAA20+
Страница 1: ...INSTALLATION MANUAL PAA20 V 2 0 ...
Страница 40: ...Figure 7 2 7D INSTALLATION MANUAL PAA20 V 2 0 10 2021 40 Figure 7 2 7E Figure 7 2 7F ...
Страница 110: ...9 2 OUTPUT 2 CONNECTOR Figure 9 2A Picture 9 2B INSTALLATION MANUAL PAA20 V 2 0 10 2021 110 ...
Страница 111: ...9 3 OUTPUT 3 CONNECTOR Figure 9 3A Figure 9 3B INSTALLATION MANUAL PAA20 V 2 0 10 2021 111 ...
Страница 112: ...9 4 INPUT CONNECTOR Figure 9 4A Picture 9 4B INSTALLATION MANUAL PAA20 V 2 0 10 2021 112 ...
Страница 114: ...9 5 2 INPUT WITH A POSITIVE COMMON Picture 9 5 2A INSTALLATION MANUAL PAA20 V 2 0 10 2021 114 ...