40
Picture 60: Switching Outputs Q1, Q2 and Q3
Picture 61: Settings for output Q1...
15.3 Switching Outputs
In the
Switching outputs
menu you can freely set different parameters for the switching outputs
defined as Q1, Q2 e Q3.
You can set independent parameters for each of the three switching outputs Q1, Q2 e Q3. In this
example we describe settings for output Q1. Similarly, parameters for outputs Q2 and Q3 can be set.
Distance values are given in mm.
Active range (measuring window)
In the boxes
active range from
and
up to
you define the distance starting from the front edge of the
sensor housing up to the target; output Q1 will be react in this range.
For example: By entering from 500 mm to 1000 mm, you cause output Q1 to switch as soon as the
LMB detects an object at least at 500 mm distance from its housing. As soon as the object distance
gets higher than 1 m, the output reverts to its initial condition.