Page 65 of 69
Proton Products InteliSENS DG2030 Diameter Gauge Instruction Manual (Issue 1a)
DW
Bit
Comments
Unit
Range/Remark
Default value
DW125
Gain of analogue input
1=1
10000
DW126
Zero of analogue input
1=1
0
DW127
Parameter Group Number
1~50; 0 is not used
1
DW128
Parameter Group Control
1=Load parameters
from specified
group;2=Save current
parameters to specified
group
0
DW129