![Proton InteliSENS DG2030 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/proton/intelisens-dg2030/intelisens-dg2030_instruction-manual_1620407047.webp)
Page 47 of 69
Proton Products InteliSENS DG2030 Diameter Gauge Instruction Manual (Issue 1a)
L
OGIC
I
NPUTS
Logic inputs connection
Two logic inputs are fitted as standard and may be accessed through the “INTERFACE” connector.
Connector type: DB25 female (socket)
Pin Designation Description
Notes
10
LIN2
Logic input 2
11
DGND
Digital ground
Ground reference for LIN1 and LIN2.
23
LIN1
Logic input 1
S
Shield
Ensure that the cable shield is connected to this via the plug
shield connection.
Logic inputs electrical specification
•
Logic inputs are not isolated from earth.
•
Inputs are internally pulled up to +15 V
via 5.1kΩ resistors; unconnected inputs default to the high
state.
•
Inputs will source a minimum current of 3mA when externally pulled down to the low state.
Specification
Minimum
Typical
Maximum
Units
Low state (logic 0) input voltage
3
V
High state (logic 1) input voltage
10.5
V
Absolute input voltage
-30
30
V
Low state source current
3
mA
Logic inputs can be connected to different types of signal sources as follows:
Signal source
Connection method
Mechanical or solid
state relay contact
Connect between logic input and DGND (pin 11).
Pull-down
Connect the pull-down signal to the logic input and ground to DGND (pin 11).
Pull-up
•
Connect an 820
Ω resistor between the logic input and DGND (pin 11) to pull
the input down to 2.5V.
•
Connect the pull-up signal source to the logic input and ground to DGND
(pin 11).
•
For 24V signals (such as from a PLC), the power dissipation in the 820
Ω
resistor can be reduced by connecting another 820
Ω in series between the
pull-up signal source and logic input.