PECIFICATIONS
DG1130 specifications
Number of axes
1
Scan rate
600 scan/s/axis
Cumulative scan rate
600 scan/s
Update time
1.667ms
Object diameter
0.5~120 mm
Optical gate diameter
130 mm
Accuracy
± (3
μm + 0.008% of object diameter) μm
Output resolution
0.01
μm
Operating temperature
5 ~ 45°C
Environmental protection
IP65
DC Power supply voltage
18~30VDC
DC Power consumption
30W
Light source
Laser (class 2)
Air wipe
Integrated air wipe system
Measurement units
(user configurable)
millimetres (line speed: millimetres / minute, length: metres)
inches (line speed: feet / minute, length: feet)
Measurement modes
Solid
Solid object diameter
Glass
Transparent object diameter
Helix
Twisted / braided multi-core cable envelope diameter
S
TANDARD INTERFACES
2x digital inputs
User configurable function Reset, Print Activation
Maximum input voltage
24 Vdc
4x relay outputs
User configurable function
Gauge OK, Upper tolerances exceeded,
Lower tolerances exceeded, Single
Measurement Flaw Detection (SMFD)
Isolated contact rating
Maximum voltage
24 Vdc
Maximum current
1 A
Line speed inputs
Required for Helix mode or optional PI feedback controller operation
Analogue input
0 - 10 Vdc, user scalable
Speed pulse input
250 kHz max frequency, 30 V or 50 V max
pulses (on two distinct inputs), user
scalable
Communication interfaces
RS-232*, RS-422, RS-485, CAN-bus**, Ethernet
*An optional RS-232-to-USB converter cable is available for connection to USB equipped computers.
**CAN-bus protocol is proprietary and reserved for connection to other Proton Products equipment
such as a CDI4 interface display unit.