Page 12 of 68
Proton Products InteliSENS DG1130 Diameter Gauge Instruction Manual (Issue 1a)
Electrical interfaces
Must be specified for factory installation at time of ordering; cannot be field-retrofitted.
Analogue outputs
•
3x analogue (±10V) outputs.
•
Independently programmable functions for X, Y, Z
(DG3030/3060 only) diameters, average diameter, diameter
errors from preset value, ovality and ovality error.
Proton part number
00047MC062
Proportional Integral (PI) feedback controller
•
PI feedback diameter control via adjustment of insulation
extruders or capstan drives.
•
Isolated ±20V analogue input and ±10V analogue output for
connection to insulation extruders or capstan drives.
Proton part number
00047MC061
O
PTIONAL FIRMWARE
Optional firmware may be end-user enabled through the purchase of a license key. Some optional
firmware functions are dependent on the presence of optional interfaces.
Fast Fourier Transform (FFT) Analysis
FFT
•
Calculates FFT frequency spectra of measured diameters.
•
Identifies periodically occurring diameter fluctuations caused
by production line problems.
•
Essential for telecommunications cable lines where periodic
diameter fluctuations can degrade cable bandwidth.
Proton part number
00054SW013
Statistical Process Control (SPC) automatic set point control
•
Minimises insulation material consumption whilst holding the
insulation diameter in tolerance.
•
Requires the PI feedback controller interface option
(00047MC061) to be installed.
Proton part number
00054SW011
Single Measurement Flaw Detection (SMFD)
•
High-speed lump and neck flaw detection.
Proton part number
00054SW014