Page 43 of 68
Proton Products InteliSENS DG1130 Diameter Gauge Instruction Manual (Issue 1a)
PROFINET communications
The PROFINET interface is an optional extra that must be ordered for installation during
manufacture; it cannot be retrofitted to the unit.
This communications interface operates independently of the other communications interfaces and
may be used at the same time as them.
PROFINET interface
The PROFINET interface may be accessed through the “PROFI/EIP/DEV” connector.
Connector type: DB9 female (socket)
Pin PROFINET
Comments
1
LAN TX-
2
LAN TX+
7
LAN RX-
9
LAN RX+
S
Shield
Ensure that the cable shield is connected to this via the plug shield connection.
PROFINET LED indicator
i-BUS
LED status
Indication
Continuous green
Online
PROFINET communications
Continuous red
Communication error
Extinguished
No communication