- 66 -
A c c e s s o r i e s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T e c h n i c a l T r a i n i n g
Wired outdoor sensor (ref. 0020012393).
The boiler can accept a wired exterior sensor, to be wired to connector X17 of the main circuit board. In this case, the setting
parameters for the sensor are found in the installer menu (d43 and d45).
Outdoor temperature
sensor characteristics :
T°C
R (Ohms)
-25
2167
-20
2076
-15
1976
-10
1862
-5
1745
0
1619
5
1494
10
1387
15
1246
20
1128
Tank thermistor.
A type AS boiler can be associated with a tank. This tank is then controlled, either by a thermostat or a thermistor.
The thermistor is supplied as an accessory.
Tank thermistor (NTC1) characteristics
T°C
R (Ohms)
0
32600
10
19900
20
12500
30
8000
40
5300
50
3600
60
2500
70
1750
80
1260
90
920