53
Version A
Mini-Cam
Proteus ExZ1
On ATEX-1 systems, when non-compliant pressure is reached, the system should
also remove power to the inspection equipment.
You can tell that the power supply has been removed, as the camera
illumination lights will go OFF.
If the Uncompliant warning is
NOT
shown, the system is
NOT
suitable for ATEX.
For ATEX-1, if the inspection equipment power is
NOT
removed, the system is
NOT
suitable for use.
For ATEX, if any test fails, do not use the inspection equipment, and consult
your Mini-Cam Service team.
After performing these tests, the OVERRIDE key must be returned to the ATEX
position before using the inspection equipment for ATEX-1 inspections.
After manually releasing the inspection equipment pressure, it
MUST
be
re-pressurised again before use.