3.6 

PHOTOCELLS wiring

3.6.1 CLOSING Photocells

Power the CLOSING PHOTOCELLS wiring them to terminals 

7 - 8 - 9

 on 

JP5

 terminal block.

Wire the N.C. contact of the photocells to terminals 

5 - 7

 on 

JP5

 

terminal block.

The closing photocells will behave as follows: 

• 

If  an  obstacle  interrupts  the  photocell  beam  when  the 

gate  is  closing,  the  automation 

STOPS

 and 

REVERSES

 in 

about 1.5 seconds. 

•   An obstacle detected by the photocells when the gate is 

OPENING does not cause any effect.

Additional sets of CLOSING PHOTOCELLS can be wired in series 

(N.C. contact).

For safety reasons al least one set of photocells must be installed 

to protect the CLOSING area of the gate.

Note:  Should you need to temporary exclude the CLOSING 

PHOTOCELLS connections, please set              parameter 

in  the ACCESSORIES menu to           =DISABLED.

3.6.2 OPENING Photocells

P

ower the OPENING PHOTOCELLS wiring them to terminals 

7 - 8 - 9

 on 

JP5

 terminal block.

Wire the N.C. contact of the photocells to terminals 

6 - 7

 on 

JP5

 terminal block.

The opening photocells will behave as follows: 

• 

If an obstacle interrupts the photocell beam when gate is 

o

pening, the automation 

STOPS

 and 

REVERSES

 in about 

3 seconds. 

Additional sets of OPENING PHOTOCELLS can be wired in series 

(N.C. contact).

For safety reasons al least one set of photocells must be installed 

to protect the OPENING area of the gate.

Note:  Should you need to temporary exclude the OPENING 

PHOTOCELLS connections, please set              parameter 

in  the ACCESSORIES menu to          =DISABLED.

3.5 

STOP push-button wiring

Wire the STOP push-button to 

2

 and 

4

 terminals on

 JP4

 terminal block.

Additional STOP controls/push-buttons can be wired in parallel (N.C. contact)

The wiring of an emergency stop push-button is highly 

       recommended for the safety of people and objects.

Note:  Should you need to temporary exclude the STOP connections, please

 

set         parameter in the ACCESSORIES menu to          =DISABLED

.

Содержание Q80S

Страница 1: ...i Occupation function Pre Blinking function Additional radio channel optional module Built in radio receiver 433 92MHz 64 codes suitable for standard fix code transmitters or rolling code transmitters...

Страница 2: ...settings 4 PROGRAMMING pag 12 4 1 Menu RADIO pag 12 4 2 PROGRAMMING menu pag 14 4 2 1 Selecting the PROGRAMMING MODE AUTOMATIC programming mode with OBSTACLE DETECTION SEQUENTIAL programming mode pag...

Страница 3: ...nel must be performed with the control panel disconnected from the power supply Connect the control panel only to a power supply line equipped with safety grounding system Wiring settings and commissi...

Страница 4: ...EASE or START command when not programming DECREASE or PEDESTRIAN START command when not programming DISPLAY segments display J1 radio module J5 plug for optional modules F2 230V fuse 5A FR1 24V fuse...

Страница 5: ...050 Castagnito CN ITALY Tel 39 0173 210111 Fax 39 0173 210199 info proteco net www proteco net LIVE NEUTRAL EARTH CLOSE CAPACITOR FLASHING LIGTH 24V ac MAX 20w PEDESTRIAN BLACK STOP START COMMON CLOSI...

Страница 6: ...IAN START command N O contact 4 NEUTRAL for controls JP5 PHOTOCELLS and SAFETY DEVICES 5 CLOSING PHOTOCELLS terminal N C contact 6 OPENING PHOTOCELLS terminal N C contact 7 Photocells RECEIVER power s...

Страница 7: ...gate opening from left to right looking from inside the courtyard as shown in the drawing In case of gate opening from right to left please adjust parameter in accordingly to 01 see page 16 OUTSIDE I...

Страница 8: ...RIAN START controls wiring Wire the PEDESTRIAN START control push button to 3 and 4 terminals on JP4 terminal block N O contact Additional PEDESTRIAN START controls push buttons can be wired in parall...

Страница 9: ...area of the gate Note Should you need to temporary exclude the CLOSING PHOTOCELLS connections please set parameter in the ACCESSORIES menu to DISABLED 3 6 2 OPENING Photocells Power the OPENING PHOTOC...

Страница 10: ...ause any effect 3 7 SAFETY EDGE wiring 3 7 2 OPENING Mechanical Safety Edge Wire the OPENING SAFETY EDGE to terminals 6 9 on JP5 terminal block If the safety edge meet any obstacle while the gate is O...

Страница 11: ...ries to the receiver photocell N C contact If the safety edge meet any obstacle while the gate is CLOSING the automation STOPS and REVERSES An obstacle detected by the safety edge while the gate is OP...

Страница 12: ...set the dip switches on the module as shown 1 ON 2 ON 3 OFF Dip switch 4 is non influential 3 9 2 CONTROL LIGHT settings You can use the MRX01 module to control an indicator light The electric contact...

Страница 13: ...io codes on this control panel Press button and use to select menu then press button to enter the RADIO menu display will show Use buttons to scroll the lower level menu and select Saving a new remote...

Страница 14: ...ultaneously press button on the control panel The display shows the radio code position 3 If the display shows It means that memory is full and no further code can be stored Repeat steps 1 and 2 to sa...

Страница 15: ...procedure the gate will If open it start closing till the limit switch bracket meets the motor Then it opens till the opening limit position Stops and reverses till the fully closed position The contr...

Страница 16: ...Before starting this programming procedure make sure that the TORQUE POWER is not set too high in that case please adjust parameter in menu to reduce it If the control panel is programmed using this p...

Страница 17: ...n again till the display shows or wait the timeout 20 seconds to exit LIMIT SWICTHES mode 1 Use buttons to move inside the menu till the display shows 2 Press and hold button for about 5 seconds 3 Use...

Страница 18: ...ve inside the menu till the display shows 2 Press button to confirm The display now shows the current torque power level for motor 3 Use buttons to change the motor torque power level 4 Press button t...

Страница 19: ...IONS menu Use this menu to enable disable special settings function is ON function is OFF Press button and use to select menu then press button to enter the FUNCTIONS menu display will show Use button...

Страница 20: ...e timeout 20 seconds to exit PHOTOCELLS TEST Function If this function is enabled the control panel performs a quick start up test with the photocells to make sure that they are in operation 1 Use but...

Страница 21: ...osing To use this function you need to wire opening push button control to START terminals closing push button control to PEDESTRIAN START terminals 1 Use buttons to move inside the menu till the disp...

Страница 22: ...S SWITCH Mode Use these settings to control the gate by a DEAD MAN S SWITCH The gate opens closes only if the button is hold pressed as soon as the button is released the gate stops opening closing Wi...

Страница 23: ...this menu set the pause time for the Automatic Closing from 0 to 99 seconds 1 Use buttons to move inside the menu till the display shows 2 Press button to confirm 3 Use buttons to set the pause time...

Страница 24: ...onfirm 3 Use buttons to reduce increase motor deceleration time 4 Press button to go back to the top level menus then press button again till the display shows or wait the timeout 20 seconds to exit O...

Страница 25: ...ess button to enter the ACCESSORIES menu display will show Use buttons to scroll the lower level menus EMERGENCY STOP terminals 1 Use buttons to move inside the menu till the display shows 2 Press but...

Страница 26: ...iving and transmitting photocell Wire the photocells or disabled corresponding parameter please refer to paragraph 3 6 1 Check transmitter and receiver position alignment Check and remove the obstacle...

Страница 27: ...ith OBSTACLE DETECTION SEQUENTIAL Programming Procedure Reset to Default Settings for RAM openers OPENING DIRECTION of the motor LIMIT SWITCHES mode selection FORCE Menu TORQUE POWER adjustment OBSTAC...

Страница 28: ...SABLED ENABLED WIRED DISABLED Opening photocells WIRED Safety Edge NC WIRED Safety Edge 8K2 WIRED Display MESSAGES Stand by Control Panel ready to work Closing PHOTOCELLS operating Opening PHOTOCELLS...

Страница 29: ...chine under provisions of 2006 42 EC Machinery Directive It complies with the essential requirements of EEC Directives 2006 95 EC Low Voltage Directive 2004 108 EC Electromagnetic Compatibility Direct...

Отзывы: