23
Q80S_2014
PROTECO S.r.l.
Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 [email protected] - www.proteco.net
DECELERATION TIME
Use this setting to adjust opening/closing deceleration time for
motor (from
1
to
10 seconds
).
Before adjusting this setting, please make sure that parameter in FUNCTIONS menu is:
=
Deceleration ON
1 Use
buttons to move inside the menu, till the display shows:
2 Press button to confirm.
3 Use
buttons to reduce/increase
motor
deceleration time:
4
Pre
ss button
to go back to the top level menus,
then press button
again till the display shows:
or wait the timeout (20 seconds) to exit.
(OFF)
(max)
(min)
PEDESTRIAN OPENING TIME
Use this setting to adjust operating time for
Pedestrian Opening for gate
(from
1
to
20 seconds
).
1 Use
buttons to move inside the menu, till the display shows:
2 Press button
to confirm.
3 Use
buttons to set Motor 1 Pedestrian opening time:
4
Pre
ss button
to go back to the top level menus,
then press button
again till the display shows:
or wait the timeout (20 seconds) to exit.
(total opening)
(min)
(max)