(*) If the module is not able to process the requested service for example the
master is requesting a slot or index that is not supported for whatever reason
then the user can set the ErrorCode1 and ErrorCode1 which will be transferred to
the master. But the ErrorCode must conform to the PROFIBUS specification.
DPS_DPV1C1_RW_RESP_CONFIRM
Parameter Data
Type
Value Meaning
Reserved1 INT
0
Reserved
Reserved2 INT
0
Reserved
Answer
SINT
17
Command for DPV1 Class 1 Read Response
Failure SINT
0 no
error
Reserved4 INT
0
Reserved
RwResp
SINT
2
2 = Write Resp Request. Reply from resp. request
MaAdr
SINT
0.. 125
Bus Address of Master which sent the request. Reply from
resp. request
Slot
INT
0.. 254
Slot Number. Reply from resp. request
Index
SINT
0.. 254
Index. Reply from resp. request
DataLen SINT 1..
240
(x)
Length of the data block to be written.
ErrCode1
SINT
E1
DPV1 Error code 1 Reply from resp. request
ErrCode2
SINT
E2
DPV1 Error code 2 Reply from resp. request
Data[1..x]
SINT[1..240]
0-255
DPV1 Write data the Master has sent.
CIP MSG Parameterization
Parameter Value
Remarks
Message Type
CIP Generic
Service Type
Custom
Service Code
64 hex
Service Code "Bridge Message"
Class
65 hex
CIP Object "CIP_MSG_BRIDGE""
Instance 1
Attribute 0
Source Element
Dpv1RWRespReq
Reference to a Tag of type
DPS_DPV1C1_RW_RESP_REQUEST
Destination
Dpv1RWRespCnf
Reference to a Tag of type
DPS_DPV1C1_RW_RESP_CONFIRM
Source Length
16
Corresponds to the constant size of DPS_DPV1C1_RW
_REQUEST structure
DPV1 Class 1 Alarm Request
The DPV1 Class 1 Alarm Request is used to indicate a DPV1 Alarm to the
connected Master. The MSG instruction Request/Confirmation format is as
follows.
DPS_DPV1C1_ALARM_REQUEST
Parameter Data
Type
Value Description
Reserved1 INT
0
Reserved
Reserved2 INT
0
Reserved
Reserved3 INT
0
Reserved