ILX69-PBM ♦ CompactLogix™ or MicroLogix™ Platform
Communication
PROFIBUS Master Communication Module
User Manual
ProSoft Technology, Inc.
Page 67 of 113
GLOBAL-BITS
Bit
Offset
Member
Name
Data
Type
Signification
Meaning if Bit is set
0
Ctrl
BOOL
CONTROL-ERROR
Parameterization error
1
Aclr
BOOL
AUTO-CLEAR-ERROR
Module stopped communication with
all slaves and reached the auto-clear-
end state.
2
Nexc
BOOL
NON-EXCHANGE-ERROR
At least one slave has not reached the
data exchange state and no process
data will be exchanged.
3
Fat
BOOL
FATAL-ERROR
Because of major bus error, no further
bus communication is possible.
4
Eve
BOOL
EVENT-ERROR
The module has detected bus short
circuits. The number of detected
events is contained in the
Bus_error_cnt variable. This bit is set
when the first event was detected and
will remain set.
5
NRdy
BOOL
HOST-NOT-READY-
NOTIFICATION
Indicates if the Application program
has set its state to operative or not. If
this bit is set the Application program
is not ready to communicate
6
Tout
BOOL
TIMEOUT-ERROR
The module has detected an
overstepped timeout supervision value
because of rejected PROFIBUS
telegrams. It is an indication for bus
short circuits while the master
interrupts the communication. The
number of detected timeouts is
available in the Time_out_cnt variable.
This bit will be set when the first
timeout is detected and will remain set.
7
Reserved1
BOOL
Reserved
Reserved, set to 0
Byte
Offset
Structure
Member
Data
Type
Description
24 to 39 Sl_cfg[16]
SINT(16)
List of Configured Slaves (Bit Field)
40 to 55 Sl_state[16]
SINT(16)
List of Activated Slaves (Bit Field)
56 to 71 Sl_diag[16]
SINT(16)
List of Faulted Slaves (Bit Field)