background image

IMPORTANT INFORMATION AND SAFETY PRECAUTIONS - PLEASE READ CAREFULLY PRIOR TO INSTALLATION
INTENDED USE FOR THE PROPUR® HOME WHOLE HOUSE WATER FILTRATION SYSTEM:

 This 

SYSTEM

 is designed for 

point-of-entry installation for residential use in filtering either municipal or well potable water. To validate the 

warranty, installation, use and maintenance of the Propur 

HOME

 system must conform to specifications, 

limitations and instructions stated within this manual. For well water use, we recommend your water be 

tested for pH, hardness, iron and bacteria. Iron level >.3 mg/I, may require a water softener system (Propur® 

PH-2000) as this could affect the performance of the 

SYSTEM

. The use of a Pre-sediment filter and other 

equipment may be necessary to address your particular water condition(s), and if necessary, to protect the 

SYSTEM.

 Propur® offers a City Water Test Kit and Well Water Test Kit for checking water. Visit your authorized 

Propur® dealer or 

www.propurusa.com. 

WARNING

1. Do 

NOT

 use with water that is microbiologically unsafe or of unknown quality without adequate  

 

disinfection before the system

2. Do 

NOT

 install the system or adjacent filter housing(s) near electrical wiring or piping which may be in 

 

the path when securing 

SYSTEM 

to a wall

3. Do 

NOT

 install 

SYSTEM

 on its side or in direct sunlight

4. 

SYSTEM

 should be installed in a dry location protected from the elements including freezing

5. 

Should the home electrical system require the use of the cold water system as an electrical safety 

 

ground, a jumper 

MUST 

be used to ensure a sufficient ground connection across the filter system 

 installation. 

6. Pressure 

MUST

 be released in the ElectroCharged™ Sub-micron filter assembly prior to removing the 

 

filter sump

CAUTION

1. 

Be careful not to over-tighten any connections to avoid damage or cracks to connections which 

 

could result in damage and or leaks

2. 

Use only approved thread sealant such as Teflon tape or Teflon paste when making connections. 

 

When using paste thread sealant, label must state suitable for use with PVC and NSF approved. 

 

Some sealant pastes may contain solvents which can soften threads resulting in damaged fittings 

 

and leakage

3. 

If an irrigation/sprinkler system is present upstream of the system, a one-way check value 

MUST 

be 

 

installed to protect your 

SYSTEM

4. 

Installation such as apartment dwelling may require a vacuum breaker valve

5. 

For well water installation, install 

SYSTEM

 after pressure tank 

6. 

For city water installation, install 

SYSTEM

 after meter

7. 

In areas of known high sediment (such as New York), a Pre-sediment filter assembly is recommended

8. 

ElectroCharged™ Sub-micron filter assembly requires 3” of space below sump in order to replace 

 filter

9. DO 

NOT 

install where ambient temperature may go above 110°F (43.3°C)

10. DO 

NOT 

install without a pressure limiting valve should the water pressure exceed 100 psi (690kPa).

11. DO 

NOT 

install on the hot water supply line

12. 

Fuel or electrical power supply going to water heater may need to be shut off during installation 

 

after water supply is shut off

13. 

To avoid risk of property damage due to water leakage or to replace tanks or filter cartridge, a 

 

bypass line with ball valves 

MUST 

be installed as shown in Assembly Diagram

14.

 The 

SYSTEM

 

MUST 

be flushed/purged before being connected to the main plumbing. This helps 

 

prevent media fines from discharging into the home plumbing and water appliances. Follow 

 

instructions (

16

) under GETTING STARTED

IMPORTANT NOTES

1. 

Before starting installation, shut off main water supply, drain pipes and release pressure as necessary

2. 

Check for leaks after completing installation

3. 

Failure to follow instruction manual will void warranty

Содержание ProMax

Страница 1: ...e Haloacetic Acids Microcystin and micro plastics See the com plete lab report on the Propur HOME system at www propurusa com Propur HOME SYSTEM OVERVIEW SYSTEM INCLUDES 3 stage filter tank assembly with rack 6 push fit connectors 3 connector tubes and tube supports 1 ElectroCharged Sub micron filter assembly with wrench and mounting bracket 5 PEX tubing with tube supports READ CAREFULLY AND FOLLO...

Страница 2: ... careful not to over tighten any connections to avoid damage or cracks to connections which could result in damage and or leaks 2 Use only approved thread sealant such as Teflon tape or Teflon paste when making connections When using paste thread sealant label must state suitable for use with PVC and NSF approved Some sealant pastes may contain solvents which can soften threads resulting in damage...

Страница 3: ...endent on specific water source and usage For well water application check iron level Above 3 mg I call for information as this may require a water softener Pre sediment filter optional When sediment may be of concern we recommend the installation of a Pre sediment filter assembly Item PH PRE filter assembly Recommended filter cartridge replacement up to 6 months or as needed Depending on your spe...

Страница 4: ...Charged Sub micron following tank 3 8 Tanks are pre filled at the factory ElectroCharged Sub micron filter assembly comes with replaceable filter cartridge 9 DO NOT use pipe solvent dope as some types may cause damage to plastic fittings 10 DO NOT overtighten as it may cause damage to components and or property 11 Determine location for SYSTEM and make sure SYSTEM is connected with the correct flo...

Страница 5: ...iscolored indication the Sub micron filter cartridge should be replaced b Replacement instructions i TURN OFF MAIN WATER SUPPLY INLET and OUTLET WATER VALVES ii Place a bucket under the filter housing assembly to catch excess water iii Relieve water pressure by pressing red button on Sub micron filter assembly head iv Unscrew clear housing sump using supplied wrench and slowly turn to the left unt...

Страница 6: ... THE PART OF PP WITH RESPECT TO PRODUCTS SOLD BY PP ARE DISCLAIMED EXCEPT FOR ANY EXPRESS WAR RANTIES ALL PROPUR PRODUCTS ARE SOLD AS IS PP shall not be held liable for any incidental consequential or special damages of any sort whatsoever The liability of PP is limited to the original retail purchaser and to the repair or replacement of defective components during the Warranty Period No refunds w...

Отзывы: