16.
Surge flushing: It is important to surge flush the
SYSTEM
prior to final connection/installation to
household plumbing and use to prevent carbon media fines or carbon dust from discharging into
the household plumbing and water appliances.
a.
Install temporary line at OUTLET of Sub-micron filter assembly to allow water to drain out
b.
BYPASS LINE valve should be turned off
c.
Slowly turn on the water supply line. You may notice discolored and or cloudy water due to carbon
fines flowing into the drain. This is normal as the
SYSTEM
is being flushed out. Continue to slowly turn
on and flush until clear water free from discoloration and cloudiness is flowing
d.
Once completed, disconnect the temporary line at OUTLET and finish connection/installation to the
household plumbing line
17.
Make sure
SYSTEM
is firmly attached and supported
18.
Once installation is complete, reinstall ElectroCharged™ Sub-micron filter cartridge into housing.
Slowly turn on water supply line and press red button on filter head to release air pressure
19.
Run system and inspect for any leaks
20.
Should water appear cloudy in a glass, this is normal as there maybe air bubbles still in the system
and will dissipate with use
MAINTENANCE
1.
USE OF BYPASS LINE: BYPASS LINE is intended to be used when circumventing the system for
maintenance or repair of
SYSTEM
. To use,
a.
Shut off the main supply line and open faucet to release pressure
b.
Close the INLET and OUTLET valve and open the BYPASS line valve
2.
ElectroCharged™Sub-micron filter cartridge replacement – recommend every 6 months or;
a.
Should there be a noticeable reduction in water flow, change in taste or if the filter
cartridge becomes heavily discolored, indication the Sub-micron filter cartridge
should
be
replaced.
b.
Replacement
instructions
i.
TURN OFF MAIN WATER SUPPLY, INLET and OUTLET WATER VALVES
ii.
Place a bucket under the filter housing assembly to catch excess water
iii.
Relieve water pressure by pressing red button on Sub- micron filter assembly
head
iv.
Unscrew clear housing sump using supplied wrench and slowly turn to the left
until sump is detached from assembly head. Discard old filter cartridge. Wash
sump thoroughly with mild soap and water. Rinse well. DO NOT place in
dishwasher.
v.
Remove and lubricate O-ring with food grade oil
vi.
Insert new cartridge and re-install sump housing. Be sure O-ring is positioned
correctly in the proper groove before tightening onto the head. Tighten using
supplied wrench only. Caution not to overtighten as damage and or leakage
could
occur.
vii.
Slowly turn on main water supply and open INLET and OUTLET valves
viii.
Press red button on head to release air pressure and check for leaks
ix.
Flush system for several minutes.
x.
You are now ready to use.
3.
Manufacturer recommends ElectroCharged™ Sub-micron filter housing assembly be replaced every
4 years to maintain warranty
4.
Use only warm, soapy water to clean the outside of the 3 stage filter tank housings. Rinse well with
fresh, clean water. Never use chemical cleaning products on the filter’s housing exterior surface as
this may cause damage to the housings.
5.
3 stage tank assembly replacement
a.
Shut off the main water supply line, INLET and OUTLET valves
b.
Disconnect the INLET and OUTLET side of the 3 stage tank assembly
c.
Disconnect the ElectroCharged™Sub-micron filter assembly from 3 stage tank
assembly
d.
Depending on the installation, the rack may need to be detached from the wall in
order pull out (slide) the 3 stage tank assembly from the rack
e.
Continue replacement installation with step 16 through step 20