CHAPTER 5
5.40
FAULT
CAUSE
REMEDY
Insufficient tractor hydraulic
pump output, tractor
hydraulic pump is damaged.
Check the tractor's hydraulic
pump.
Damaged or contaminated
cylinder
Check cylinder piston (bending,
corrosion), check cylinder for
tightness (piston seal), repair or
replace cylinder if needed.
Excessive load of the
cylinder
Check mechanisms controlled by
cylinder for mechanical damage
Damaged hydraulic lines
Check and ascertain that hydraulic
conduits are tight, not fractured
and properly tightened. If
necessary replace or tighten.