Data
Value Unit
Max. temperature, long-term at max. oper‐
ating pressure
90 °C
Max temperature, for 15 minutes at max. 2
bar
120 °C*
Minimum temperature.
-10 °C
* not in areas at risk from explosion
15.5.3 Air humidity
Air humidity, max. 92 % relative humidity, non-condensing.
15.6 Installation height
Data
Value Unit
Maximum installation height*:
1000 m above
standard
zero
* with standard pumps: Fit at higher installation heights at your own risk.
with ATEX pumps: We urgently advise that you contact a specialist for
ATEX motors at higher installation heights!
15.7 Motor data
Identity code
specification
Phases, protec‐
tion
Rated voltage
Mains frequency
Rated output
Remarks
S
3-phase, IP 55
220-240 V /
380-420 V
50 Hz
0.25kW
265-280 V /
440-480 V
60 Hz
0.25 kW
T
3-phase, IP 55
220-240 V /
380-420 V
50 Hz
0.25 kW
With PTC, speed
control range 1:5
265-280 V /
440-480 V
60 Hz
0.25 kW
R
3-phase, IP 55
230 V/400 V
50/60 Hz
0.37 kW
with PTC, speed
control range
1:20, with
external fan 1-
phase 230 V;
50/60 Hz
V0
1-phase AC, IP
55
230 V ±5 %
50/60 Hz
0.37 kW
Variable speed
motor with inte‐
grated frequency
converter, control
range 1:20
M
1-phase AC, IP
55
230 V ±5 %
50/60 Hz
0.18 kW
N
1-phase AC, IP
55
115 V ±5 %
60 Hz
0.18 kW
Liquid end SST, SSF
Air humidity
Electrical data
Technical data
65