Only use the pump to meter liquid feed chemicals.
n
Pumps with the identity code option "Multi-layer safety diaphragm with
rupture signalling (contact)" are only approved for use with flammable
feed chemicals with electrically conductive dosing heads, at back
pressures of over 2 bar and only if the operator takes appropriate
safety measures.
Pumps with the identity code option "Multi-layer safety diaphragm with
rupture signalling (contact)" are only approved for use with hazardous
feed chemicals, at back pressures of over 2 bar and only if the oper‐
ator takes appropriate safety measures.
n
Pumps with the identity code option "Multi-layer safety diaphragm with
rupture signalling (contact)" are only approved for use with hazardous
feed chemicals, at back pressures of over 2 bar and only if the oper‐
ator takes appropriate safety measures.
n
Only "H - Hygienic head" design of pumps may be used for applica‐
tions in accordance with the hygiene requirements of closed pro‐
cesses and wet cleaning without dismantling.
n
Only use the pump once it has been correctly installed and started up
in accordance with the technical data and specifications contained in
the operating instructions.
n
Observe the general limitations with regard to viscosity limits, chem‐
ical resistance and density - see also the ProMinent Resistance List
(in the Product Catalogue or at www.prominent.com)!
n
All other uses or modifications are prohibited.
n
The pump is not designed to meter gaseous media and solids.
n
The pump is not intended for the metering of explosive substances
and mixtures.
n
The pump is not intended for unprotected use outdoors.
n
The pump is not intended for private use.
n
Only trained and authorised personnel should be allowed to operate
the pump - see the table below.
n
You have a duty to observe the information contained in the operating
instructions during the different phases of the service life of the unit.
n
You have a responsibility to observe the information contained in the
operating instructions for the auxiliary equipment at the different
phases of its respective service life.
n
ATEX designs only: Refer to the chapter "
mation for ATEX designs’ on page 14
".
2.3 Personnel qualification
Task
Qualification
Storage, transport, unpacking
Instructed person
Assembly
Technical personnel, Service
Planning the hydraulic installation
Qualified personnel with a thorough knowledge of oscillating displacement
pumps
Hydraulic installation
Technical personnel, Service
Electrical installation
Electrical technician
Start up
Technical personnel
Operation
Instructed person
Maintenance, repair
Technical personnel, Service
Decommissioning, disposal
Technical personnel, Service
Troubleshooting
Qualified person, electrical technician, instructed person, Service -
depending on the requirement