Tab. 13: Fuses
Fuse
Value
Order No.
Fuse, internal
10 AT - (1.5 kA)
733855
Only use the original fuses from ProMinent! It is not suffi‐
cient to use a fuse with the above fuse rating.
16.8 Diaphragm rupture sensor
Tab. 14: Contact loading, max.
at voltage
Maximum current
30 V DC
1 A
The contact is an opener.
The contact is an potential-free.
–
For safety reasons we recommend connecting to a
protective low voltage, e.g. in accordance with EN
60335-1 (SELV ).
–
The cable can be poled as required.
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Data
Value Unit
Rated voltage *
8 VDC
Power consumption - active surface
uncovered
> 3 mA
Power consumption - active surface cov‐
ered
< 1 mA
Rated switching distance
1.5 mm
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
16.9 Relay
The technical data for the relay are contained in the
chapter "Installation, electrical".
Contact (standard)
Namur sensor (Specified for EX zones)
Technical data
90