With
‘metering optimised’
‘metering profile’
, the discharge stroke is elon‐
gated, the suction stroke is executed as quickly as possible. This setting is
suitable, among other things, for applications that require optimum mixing
ratios and chemical mixing that is as continuous as possible.
Under
‘Metering profile’
-
‘priming optimised’
, the suction stroke is elon‐
gated as much as possible, which makes possible the precise and
problem-free metering of viscous and gaseous media. Select this setting
to minimise the NPSH value as well.
With
‘Metering profile’
-
‘Standard’
the pump meters as usual.
9.3.2.2
‘Pressure stage’
‘Menu / Information
è
Settings
è
Metering
è
Pressure stage
è
...’
With
‘Metering
è
Pressure stage’
you can reduce the nominal pressure of
the pump via the pressure stages – refer to the "Functional description”
chapter.
When selecting a pressure stage, you are simultaneously selecting the
error behaviour.
Tab. 5: Nominal pressures depending on the size of the liquid ends and the pressure stages
Pressure stage /
4
7
10
12
Size of liquid end
120145 *
X
X
X
X
120190 *
X
X
X
X
120270 *
X
X
X
X
070410
X
X
-
-
070580
X
X
-
-
040830
X
-
-
-
* the pressure of the plastic liquid ends is reduced to 10 bar.
9.3.3
‘Calibration’
‘Menu / Information
è
Settings
è
Calibration
è
...’
Accuracy of calibration
Normally the pump does not have to be calibrated.
The pump can be calibrated if viscous feed chemicals
are used or extremely high accuracy is required.
Metering optimised
Priming optimised
Standard
Pressure stage
Set up /
‘Menu’
51
Содержание S3Cb
Страница 102: ...Spare part Type 120145 120190 120270 Valve 803708 Multi layer diaphragm 1029604 Liquid ends for Sigma 3 102 ...
Страница 107: ...PTFE FDA No 21 CFR 177 1550 PVDF FDA No 21 CFR 177 2510 Wear parts for S3Cb 107 ...
Страница 121: ...121 ...
Страница 122: ...122 ...
Страница 123: ...123 ...