![Prometal UNIVERSAL 1000 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/prometal/universal-1000/universal-1000_maintenance-manual_1616666016.webp)
Maintenance manual Universal-1000
P R O M E T A L
16
unbalance weights should be pushed by hand and must then oscillate. If this is not the case,
then it is most likely the sign of imminent bearing damage.
-Mould support-
Check condition of rubber profiles and bronze strips in mould holders, particularly on mould
replacement. Secure loose parts and renew damaged ones. Renew damaged or worn bushings.
-Filler box table and hopper-
Check tightness of bronze wear strips on end faces of filler-box tables. Secure loose strips;
renew if damaged or severely worn. Check scraper plates of filler-box tables and replace if
necessary.
Check functioning of hopper outlets. Renew worn bolts and bronze bushings in mount. If
level indicators are fitted, check cables for damage and renew if necessary.
Содержание UNIVERSAL 1000
Страница 19: ...Maintenance manual Universal 1000 P R O M E T A L 19 ...
Страница 25: ...Maintenance manual Universal 1000 P R O M E T A L 25 Hydraulic system ...
Страница 26: ...Maintenance manual Universal 1000 P R O M E T A L 26 ...
Страница 27: ...Maintenance manual Universal 1000 P R O M E T A L 27 Basic principles for the installation of hose assemblies ...
Страница 51: ...Maintenance manual Universal 1000 P R O M E T A L 51 This is followed with unscrewing all screws ...
Страница 52: ...Maintenance manual Universal 1000 P R O M E T A L 52 Now lower down tamper head and mould ...
Страница 53: ...Maintenance manual Universal 1000 P R O M E T A L 53 Pull out cart with mould on itself ...
Страница 58: ...Maintenance manual Universal 1000 P R O M E T A L 58 After adjustment is done ...
Страница 65: ...Maintenance manual Universal 1000 P R O M E T A L 65 Vibrator table maintenance ...