Promation Engineering P1.A Series Скачать руководство пользователя страница 18

Industrial Applications

ProMation Engineering actuators have been installed to operate process controls such as butterfl y 

valves, ball valves, high performance valves, plug valves, gate valves and dampers, in a broad 

range of demanding industrial applications.

Power 

Generation

Water 

Processes

Mining

Oil and Gas

Agriculture

Chemicals

16138 Flight Path Drive 

Brooksville, FL 34604

Phone (352) 544-8436   Fax (352) 544-8439

email: [email protected]

    

Complete Support

Full Documentation 

We offer complete wiring diagrams, fi eld installation manuals and set up 

documentation for all our products, both in printed and digital form. We 

regularly host customized educational webinars for our customers.

RapidQuote

Most quotes and estimates are generated within hours of the request.

ProMation Engineering Services 

ProMation Engineering can provide design and technical services for 

OEM’s, projects with customized requirements and specialized operations.

ProMation Engineering is committed to providing superior customer support 

for your sales, project management and installation teams. Contact us today.

ProMation Engineering follows a policy of continual product updates and enhancements. Our website 

is the best place to obtain the latest product documentation, including the wiring diagrams for these 

controllers. 

Visit us at www.promationei.com or use the code to link to the site.

Use your smart phone barcode 

scanner app here.

Содержание P1.A Series

Страница 1: ...Installation Operation Manual This IOM is for the following ProMation Engineering Products P1 A 12VN4 AC P1 A 12VN4 DC P1 A 24VN4 AC P1 A 24VN4 DC...

Страница 2: ...This page intentionally left blank...

Страница 3: ...ts 2 Product Specifications 3 Shipping and Handling 3 Product Mounting and Setup 3 Installation Notes 4 Wiring Diagram 5 Layout of Controller 6 Check End of Travel Settings 6 Check End of Travel Setti...

Страница 4: ...e Duty Cycle is directly related to heat excessively repositioning an actuator typically results in motor overheating which can cause permanent damage and or reduced service life Duty cycle can be cal...

Страница 5: ...y CCW positions BEFORE applying power to the unit Warning DO NOT operate manual override when power is present Geartrain damage and personal injury may occur Do not use powered tools to turn the manua...

Страница 6: ...d do not exceed the indicated length of the wire run for each model Proportional Control MAX distance between Actuator and Supply feet Actuator Voltage P1 A 12VAC DC P1 A 24VAC DC 1 5A 0 9A 18 55 184...

Страница 7: ...D Running CCW Indicator Green LED Proportional Control DIP Switch Setting Default Functions DIP 1 Off Run Mode DIP 1 On Calibration CAL Mode DIP 2 Off Direct Acting Mode DIP 2 On Reverse Acting Mode D...

Страница 8: ...d of Travel cams have set the rotation for 90 travel Reset to 90 travel and AutoCalibrate Power On DIP 5 on No Motor Movement Red or Green Motor Direction LEDs Flash Low Power Incoming Power too low T...

Страница 9: ...tate the hex key to the LEFT 10 15 degrees to reset the switch roller arm Then snug the set screw up against the camshaft CW until slight pressure is felt Then SLOWLY rotate the hex key to the RIGHT u...

Страница 10: ...the CW auxiliary switch adjustment Drive the actuator to its CW position Then use a 2 5mm hex key to free up the cam set screw Once it is free rotate the hex key to the LEFT 10 15 degrees to reset th...

Страница 11: ...Pushed square dimension to three decimal places KHL REV A B C D E F Drive Coupling Fabrication Data 17 00 13 00 mm 0 669 0 005 0 000 in 17 00 13 00 mm 0 669 0 005 0 000 in 17 00 mm 0 669 in 127 mm 5 0...

Страница 12: ...is provided in the table belowtoshowthechange of statepointsduring the rotation of the actuator from CCW to CW and back again The red bar shows when that terminal makes with its respective common Swi...

Страница 13: ...ator I The actuator OUTPUT shaft will drive to the full CCW position while the INDICATOR cam shaft rotates to the full CW position as viewed from ABOVE the actuator II If this is NOT the correct stop...

Страница 14: ...ves actuator to fully CW 7 The CW End of Travel switch opens and motor stops 8 The Green LED goes on and motor drives to fully CCW 9 The CCW End of Travel switch opens and motor stops 10 Red LED goes...

Страница 15: ...otor drives to Fully CCW 4 The CCW End of Travel switch opens and motor stops 5 Red LED goes on and actuator drives to Fully CLOSED 6 The controller performs an internal Calibration of the Feedback Bl...

Страница 16: ...n Pass Feedback Calibration Fail 20Hz Blink 30 seconds 1Hz Blink Inde nitely 20Hz Blink 3 seconds NO YES Did the Blue LED flash at 20Hz for three 3 seconds DIAG DIAG DIAG Check that Wire Jumper connec...

Страница 17: ...ProMation Engineering Inc 16138 Flight Path Drive Brooksville FL 34604 Phone 352 544 8436 Fax 352 544 8439 www promationei com...

Страница 18: ...igital form We regularly host customized educational webinars for our customers RapidQuote Most quotes and estimates are generated within hours of the request ProMation Engineering Services ProMation...

Отзывы: