Promag WEC200 Скачать руководство пользователя страница 2

 

This device complies with Part 15 of the FCC .   
Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful 
interference, and (2) this device must accept any 
interference received, including interference that 
may cause undesired operation. 

1. General Information 

 

1-A. Model Classification: 

 

WEC 200 - 00 

 

1

     

2

     

3

 

1

Model name:  WEC (Wiegand Ethernet Controller) 

2

Model number: 200 

3

Type:  00

 standard   

 

1-B. Accessories 

a. WAS-1499 for LAN cable. 

b.  5 Pin Wiegand Input (CN2-L35005-T01-G) 

c.  10 Pin Output (CN2-L35010-T01-G) 

 

1-C. Key features 

 

Network-enable Wiegand Reader device 

 

The beep mode of BUZZER is adjustable. 

 

Two relay outputs are set, each relay includes Action (N.O.)/Non Action (N.C.)/Common Contact 

 

Two input contacts are set. 

 

Able to output Wiegand (raw data), or Facility Code (Site Code) and Card Code directly.   

 

If your computer is equipped with one RJ45 port, you are able to connect the 10/100BaseT 

Ethernet, and support TCP/IP, UDP with your Wiegand reader through WEC200.   

 

Featuring of unduplicated service code   

 

Able to define the machine ID and name from users

’ end. 

 

2. Introduction 

Points to follow to ensure correct use of the controller 

  WEC200 applies Ethernet technology to do the communication, which is important respectably 

when working on the program applying Ethernet technology.    Thanks to WEC200 converter, which is 

built-in Ethernet module featuring: 

i. 

The working Ethernet package will transform all Data into Serial Signal.   

ii. 

The Data will be sent to MCU, the internal of WEC200. 

 

Please refer to 

Chapter 5

 for framework and useful tips of WEC200     

Please refer to 

Chapter 6

 for the functions of MCU   

 

The package tool named 

DS manage

r

” and “

Connection wizard

” should be attached, which 

both equip you rapidly to set a virtual COM port.    With connecting to WEC200, you may run the   

Содержание WEC200

Страница 1: ...tion Chapter 3 Installation Chapter 4 Pin Assignment Chapter 5 How to integrate with Access Control Chapter 6 Protocol Chapter 7 Communication Ethernet Module Chapter 8 Specification Appendix A LED2 S...

Страница 2: ...Code and Card Code directly If your computer is equipped with one RJ45 port you are able to connect the 10 100BaseT Ethernet and support TCP IP UDP with your Wiegand reader through WEC200 Featuring of...

Страница 3: ...0 D1 for connection 4 wire connection is a must have to short distance communication which is good enough but to long distance wiring will be too much trouble We suggest applying 2 WEC200 to serve as...

Страница 4: ...hich is fail LED1 Green normally displays the status of the Ethernet Port When receiving an Internet package the LED1 will be cut off temporarily until the package is received entirely 4 C DC JACK Pin...

Страница 5: ...closed N C What is N O It means when deactivation is appearing the status for the electric lock is unlock otherwise if activation is appearing for the electric lock the status will be switched to lock...

Страница 6: ...least for the power supply WEC200 itself is causative which its consumable current stays at 150mA The running electric locks on the market exceed in this value widely In order to prevent the power co...

Страница 7: ...Please refer to the example we illustrate Applying a separate power supply at DC12V output which is good enough to supply the power requirement for both of electric lock and alarm The part of lock is...

Страница 8: ...ware Number V Version Y Revision For example STX ROM0722A7 CR 6 B Get service code HOST to DEVICE 4 bytes STX G S CR 02H 47H 53H 0DH DEVICE to HOST 12 bytes STX XXXXXXXXXX CR You can get the unique se...

Страница 9: ...o HOST 3 bytes STX X CR You can get the type with this command X 0 receive only 1 transmit only default 6 G Get format status HOST to DEVICE 4 bytes STX G F CR 02H 47H 46H 0DH DEVICE to HOST 3 bytes S...

Страница 10: ...s n 255 relay 1 keeping in close status 6 K Set relay2 output status HOST to DEVICE 5 bytes STX S A n CR 02H 53H 41H byte 0DH DEVICE to HOST 3 bytes STX ACK NACK CR You can activate relay2 n 0 1s stat...

Страница 11: ...status a string data will go automatically by STX C CR to give you the notice of input is changing due to 0 1 s has detected itself It implied that several messages might send out already After receip...

Страница 12: ...band UDP T inband TCP or command phase TCP e error status no errors detected E running in the error mode i IP address status not obtained yet I obtained via DHCP M fixed set manually c data connectio...

Страница 13: ...Data _ A0 2 3 5 0 62 192 168 100 216 Note 1 This is a broadcasts command so the remote host IP needs to be set to 255 255 255 255 2 The default password is blank 3 For more details please refer to the...

Страница 14: ...k1 RemoteHost 192 168 100 216 Winsock1 SendData PS01 Note 1 For more details please refer to the on line help file of DS Manager tibbo_docs chm on Set I O Pin Status Sx instruction section 7 B Reply C...

Страница 15: ...consumption 140mA 12VDC Protocols Communicates with server on the networking using TCP or UDP protocols Indication type Three LEDs display status information One built in buzzer 2 sets of input 2 set...

Страница 16: ...nection TCP or UDP with any network host is currently established Sending ARP Displayed when the DS is sending ARP requests to find out the MAC address of the destination network host with which the D...

Страница 17: ...S S S C C C C C C C C C C C C C C C C P P E E E E E E E E E E E E O O O O O O O O O O O O P Summed for even parity E Summed for odd parity O Wiegand interface 30 bit format 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 18: ...O O O O O O O O O O O P Summed for even parity E Summed for odd parity O Wiegand interface 38 bit format 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35...

Страница 19: ...EC200 00 and WEC200 01 To detail this for example if the tag code is FC177ID25111 then for WEC200 00 it will be packaged as Hex 02h 57h 46h 43h 31h 37h 37h 49h 44h 32h 35h 31h 31h 31h 0Dh W F C 1 7 7...

Страница 20: ...U program This chapter doesn t open all the commands Only list some of them that customer may use Reboot Description Reboot the WEC200 01 device Command Hex 05h 54h 45h 1Ah T E The command package sta...

Отзывы: