Promag WEC200 Скачать руководство пользователя страница 16

 

16 

 

Appendix A. LED2 Status 

Please see the following illustrations, LED indicates (example), 

  Represents Green and Red flash 3 times in chorus

.    As LED2 is 

dual display for 

configuration, you 

may see orange color flash 3 times visually. 

    Red LED makes one long blink followed by two short ones 

DS aims at the EM module located inside WEC200. 

 

Accordingly, please see the following patterns: 

  

Powerup pattern.

 This pattern is played once when the DS is switched on. 

 

 

Buzz pattern.

 Both LEDs blink fast. this pattern is played when the DS receives the 

Buzz (B) command

. This 

is used to identify a particular DS.    Please note that this is unrelated 6-E(BUZZER), DS is just receiving the order itself. 

(BUZZER). 

Error mode.

 

  Ethernet port failure. 

  Indicates that the Ethernet port hardware is malfunctioning and 

network communications with the DS is not possible. 

  IP-address not obtained.

 Means that the 

DHCP (DH) setting

 is 1 (enabled) and the DS has 

not yet obtained its IP-address from the DHCP server. 

  Data connection is closed.

 This pattern means that no data connection (TCP or UDP) with 

any network host is currently established. 

  Sending ARP.

 Displayed when the DS is sending ARP requests to find out the MAC-address 

of the destination network host with which the DS is about to establish a connection. 

TCP connection is being opened.

 Indicates that TCP connection (either incoming or 

outgoing) is being established (i.e. SYN-SYN-ACK exchange is in progress). 

  Data connection is established (or being closed).

 Means that data UDP "connection" or 

TCP connection is currently established or that TCP connection is being closed (i.e. FIN-ACK-FIN-ACK exchange is in 

progress). 

  Data is being routed.

 This pattern is played when the data connection is established and the 

data is being routed through the DS 

  Buffer overrun (and no data routing).

 This pattern is displayed when the data connection is 

established and the routing buffer overrun has been detected (within the present data connection). 

  Buffer o data routing.

 Data routing and overrun can be displayed at the same time. 

TCP connection reset by the network host.

 Means that the TCP connection has been reset 

(using RST packet) by the network host (not by the DS itself).

 

 

Above list shows frequent status, any details please visit Tibbo at 

http://www.tibbo.com

 

 

Содержание WEC200

Страница 1: ...tion Chapter 3 Installation Chapter 4 Pin Assignment Chapter 5 How to integrate with Access Control Chapter 6 Protocol Chapter 7 Communication Ethernet Module Chapter 8 Specification Appendix A LED2 S...

Страница 2: ...Code and Card Code directly If your computer is equipped with one RJ45 port you are able to connect the 10 100BaseT Ethernet and support TCP IP UDP with your Wiegand reader through WEC200 Featuring of...

Страница 3: ...0 D1 for connection 4 wire connection is a must have to short distance communication which is good enough but to long distance wiring will be too much trouble We suggest applying 2 WEC200 to serve as...

Страница 4: ...hich is fail LED1 Green normally displays the status of the Ethernet Port When receiving an Internet package the LED1 will be cut off temporarily until the package is received entirely 4 C DC JACK Pin...

Страница 5: ...closed N C What is N O It means when deactivation is appearing the status for the electric lock is unlock otherwise if activation is appearing for the electric lock the status will be switched to lock...

Страница 6: ...least for the power supply WEC200 itself is causative which its consumable current stays at 150mA The running electric locks on the market exceed in this value widely In order to prevent the power co...

Страница 7: ...Please refer to the example we illustrate Applying a separate power supply at DC12V output which is good enough to supply the power requirement for both of electric lock and alarm The part of lock is...

Страница 8: ...ware Number V Version Y Revision For example STX ROM0722A7 CR 6 B Get service code HOST to DEVICE 4 bytes STX G S CR 02H 47H 53H 0DH DEVICE to HOST 12 bytes STX XXXXXXXXXX CR You can get the unique se...

Страница 9: ...o HOST 3 bytes STX X CR You can get the type with this command X 0 receive only 1 transmit only default 6 G Get format status HOST to DEVICE 4 bytes STX G F CR 02H 47H 46H 0DH DEVICE to HOST 3 bytes S...

Страница 10: ...s n 255 relay 1 keeping in close status 6 K Set relay2 output status HOST to DEVICE 5 bytes STX S A n CR 02H 53H 41H byte 0DH DEVICE to HOST 3 bytes STX ACK NACK CR You can activate relay2 n 0 1s stat...

Страница 11: ...status a string data will go automatically by STX C CR to give you the notice of input is changing due to 0 1 s has detected itself It implied that several messages might send out already After receip...

Страница 12: ...band UDP T inband TCP or command phase TCP e error status no errors detected E running in the error mode i IP address status not obtained yet I obtained via DHCP M fixed set manually c data connectio...

Страница 13: ...Data _ A0 2 3 5 0 62 192 168 100 216 Note 1 This is a broadcasts command so the remote host IP needs to be set to 255 255 255 255 2 The default password is blank 3 For more details please refer to the...

Страница 14: ...k1 RemoteHost 192 168 100 216 Winsock1 SendData PS01 Note 1 For more details please refer to the on line help file of DS Manager tibbo_docs chm on Set I O Pin Status Sx instruction section 7 B Reply C...

Страница 15: ...consumption 140mA 12VDC Protocols Communicates with server on the networking using TCP or UDP protocols Indication type Three LEDs display status information One built in buzzer 2 sets of input 2 set...

Страница 16: ...nection TCP or UDP with any network host is currently established Sending ARP Displayed when the DS is sending ARP requests to find out the MAC address of the destination network host with which the D...

Страница 17: ...S S S C C C C C C C C C C C C C C C C P P E E E E E E E E E E E E O O O O O O O O O O O O P Summed for even parity E Summed for odd parity O Wiegand interface 30 bit format 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 18: ...O O O O O O O O O O O P Summed for even parity E Summed for odd parity O Wiegand interface 38 bit format 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35...

Страница 19: ...EC200 00 and WEC200 01 To detail this for example if the tag code is FC177ID25111 then for WEC200 00 it will be packaged as Hex 02h 57h 46h 43h 31h 37h 37h 49h 44h 32h 35h 31h 31h 31h 0Dh W F C 1 7 7...

Страница 20: ...U program This chapter doesn t open all the commands Only list some of them that customer may use Reboot Description Reboot the WEC200 01 device Command Hex 05h 54h 45h 1Ah T E The command package sta...

Отзывы: