11
6-N. Set Type
HOST to DEVICE (5 bytes)
STX
S
T
0/1
CR
02H
53H
54H
30H/31H 0DH
DEVICE to HOST (3 bytes)
STX
ACK/NACK
CR
You can set the type 0(receive)/1(transmit) by this command
The WEC200 will reboot after you execute this command.
Default: 1(transmit)
6-O. Notice Message
Notice Message is Device to send a notice to host automatically.
HOST to DEVICE (5 bytes)
STX
S
C
0/1
CR
02H
53H
43H
30H/31H 0DH
DEVICE to HOST (3 bytes)
STX
ACK/NACK
CR
When you set up auto advice by (=1), once the status of the two inputs differ from the previous status, a
string data will go automatically by STX—C—CR to give you the notice of input is changing due to 0.1(s)
has detected itself. It implied that several messages might send out already. After receipt of these
messages, apply 6-C command to get the current status of these two inputs.
Default: 0 (means no auto notice)
6-P. Auto get set up format when an variation is made
HOST to DEVICE (4 bytes)
STX
G
C
CR
02H
47H
43H
0DH
DEVICE to HOST (3 bytes)
STX “X” CR
A backup message will run automatically when the input status varies.
X
: 0—No backup/1—backup
6-Q. Notice Message
Notice Message is Device to send a notice to host automatically.
Events
Message
Card read OK
<STX>+<W>+<data bytes>+<CR>
Input status
variation
<STX>+<C>+CR
See also: Appendix C.