background image

 

 

File 

Date 

Changes on previous version 

Me Easymix 120 plus_01.docx 

 

EasyMix120plus01.mot 

 

06/09/2018 

First version from Me Eps plus3.docx 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRONIC MANUAL 

 

 

 

 

Содержание EASY MIX 120 PLUS

Страница 1: ...File Date Changes on previous version Me Easymix 120 plus_01 docx EasyMix120plus01 mot 06 09 2018 First version from Me Eps plus3 docx ELECTRONIC MANUAL...

Страница 2: ...d valve MA Beater motor MC Compressor motor MV Fan motor air version TTR Heating element Contactor TTR2 Heating element 2 Contactor TTC Compressor Contactor Set Heating or cooling set temperature TEV...

Страница 3: ...dicating the software version E g Easymix120Plus01 means version 01 In case of machine malfunction your technician will always have to mention this number as well as the machine serial number on data...

Страница 4: ...line usually shows the cycle name whereas the bottom part second line usually shows the real temperature read by TEV probe at a specific moment on the right and the temperature to be reached on the l...

Страница 5: ...5 POSITION OF SENSORS EASYMIX 120 PLUS right side view EASYMIX 120 PLUS left side view TER 2 RIGHT SIDE TES 3 LEFT SIDE TER TES TGV TES 1 TEV...

Страница 6: ...lay reads Read pasto Refer to the EVENTS paragraph read the events by releasing the Button after 6 seconds when the display shows Read Events Refer to the EVENTS paragraph reading the beater motor ope...

Страница 7: ...splay Decrease button is used also to reset the alarms The Increase button is used as well to skip a Pasteurization phase To do so hold it pressed after a cycle has started This function is enabled on...

Страница 8: ...and the display reads ex 90 PASTO 90 PASTO 65 On pressing AUTO the filling selection i e the amount of mix in the hopper is shown In this case as well place the asterisk on the side of the filling opt...

Страница 9: ...ease Decrease keys In speed change mode the display shows HEATING Set 090 05 Full Filling is always selected when the machine is started from the Stop mode Instead if Half Filling is set the cycle wil...

Страница 10: ...ed on right side TTR2 OFF Heating is reactivated with a hysteresis set in T25 When TEV reaches 40 C the display shows for 10 the following message PASTO 85 120 60 Add Powders Heating will then continu...

Страница 11: ...or anti freezing is checked Press AUTO button to display the set temperature and speed in the first page PASTO 90 120 60 Set 004 05 Press AUTO button again only with step T78 YES to display temperatur...

Страница 12: ...a cooling request is made TEV 6 C MC EVF and Beating are activated Beating is then activated with the times settable at the user s steps U08 and U09 Half Filling Cycle 60 40 Half Filling cycle is act...

Страница 13: ...rization cycles Half Filling cycle Plus is activated by placing the asterisk to the side of 60 40 Plus 120 60 60 40 full filling half filling 60 40 60 40 Plus half filling half filling plus By selecti...

Страница 14: ...perature for anti freezing is checked When TGV reaches the Anti freezing set programmable EVGC is activated until temperature is increased by its hysteresis T07 During EVGC activation EVF is deactivat...

Страница 15: ...bottom time decrease once elapsed the machine will return to Stop and mix temperature TEV followed by the set speed To change the speed press the Speed key and change it using the Increase Decrease k...

Страница 16: ...at the bottom from the left set ramp TEV Press the beating key for 10 to view the values of the 4 probes in a single page TGV 005 TER2 020 TEV 008 TER 015 To change the speed press the Speed key and c...

Страница 17: ...sound signal signaling the end of the cycle is activated HEATING 85 C 86 C The mix is thermostat controlled at the set temperature indefinitely with the same beating of the cycle carried out Note for...

Страница 18: ...015 To change the speed press the Speed key and change it using the Increase Decrease keys In speed change mode the display shows COOLING 04 C V 05 68 C Opening the lid will stop beater and cooling o...

Страница 19: ...19 SHOWER Water inlet is activated To stop it 3 options are available press the same button again press Stop after 3 minutes This function is independent from the other functions...

Страница 20: ...g M16C Flasher Once you have connected your PC USB or RS 232 to the CPU Serial with the special cable code IC577400056 USB or IC577400032 serial power the machine After installing the M16C Flasher it...

Страница 21: ...ry to disconnect the machine from power supply to hold Decrease button pressed and power the machine again to keep on holding the Decrease button pressed The display shows AUTOSETUP and then Model 03...

Страница 22: ...p of the automatic cycle values to start Values such as temperature set beating pause times will be reset to their default values in all processes The following message will be displayed AUTOSETUP PRO...

Страница 23: ...120 60 alternating with 11 47 14 Oct 10 TEV 032 TER 019 The first line shows the date and time in which the event was logged the second line shows the name of the pasteurization cycle and its filling...

Страница 24: ...ll through the events using Increase following event and Decrease previous event keys To quit Read events press STOP or do not press any buttons for 30 seconds Logged events are the various processing...

Страница 25: ...25 ELECTRONIC BOARD IMAGES The machine s electronics consist of a control unit electronic board part no IC573700148...

Страница 26: ...26 Connectors IC573700148 MRS1 230V outputs MRS2 24V outputs MRS6 power supply MRS5 NTC probes MRS4 PTC probes MRS3 inputs Not Used LCD Keyboard Not Used Serial...

Страница 27: ...necessary Alarm TER2 TER2 temperature probe switched off or short circuited The display will read Alarm TER2 and the machine will enter Stop mode if Alarm TER is also present Check TER2 temperature pr...

Страница 28: ...uring the program cycle Pressure switch Safety pressure switch tripping After 3 times the pressure switch has been triggered the machine enters STOP mode and the display reads Pressure Switch Autom ad...

Страница 29: ...will display Cool Blackout saving the event in the memory to warn the user that the product may have been altered During the Pasteurization cycles o in the heating phase when power is restored the ma...

Страница 30: ...30 the user that the cycle is repeated as the mix may have been altered as a result of the blackout TEV Temperature Time 50 C 30 minutes 49 C 15 C 10 minutes 14 C 10 C 20 minutes 9 C 4 C 2 hours...

Страница 31: ...ow all editable with the Increase and Decrease buttons will be shown in sequence To exit user programming wait for about 30 without pressing any button or press Beating to force quit The values that h...

Страница 32: ...9 Time OFF Beat When intermittent beating is selected the beater operates for a time which is programmable at step U08 and stops for a time which is programmable at this step and whose value is typica...

Страница 33: ...Hysteresis If necessary modify the step setting using the buttons and Press Stop to access the following steps In this way the steps listed in the table below all editable with the Increase and Decrea...

Страница 34: ...et TGV 060 120 C 105 T24 Max TEMP Limit 080 140 C 090 T25 Hyst Max limit 002 020 C 002 T29 EVC EVF Enabling No Yes Y N No T30 First Defrost Time 000 120 sec 010 T33 Offset TEV 000 130 C to calibrate T...

Страница 35: ...s step above the set temperature compressor and beater are reactivated to bring the product back to cooling temperature T05 Water Supply Time By pressing the water inlet button the water solenoid valv...

Страница 36: ...imit is reached TTR or TTR2 are deactivated T25 Hyst Max limit This is the hysteresis for switching on TTR again after reaching the T24 limit T29 EVC EVF Enabling When TGV reaches the Anti freezing se...

Страница 37: ...full of water and comparing the temperature of the water with the temperature read by the probes PLEASE NOTE Before installing a new probe it is important to cover it with conducting paste before thr...

Страница 38: ...ing automatic cycles for 24 hours The step returns automatically to No In case of blackout during 24h it is necessary to set this step again to Yes to display the temperatures again T86 Reset Counters...

Страница 39: ...ation 85 STEP 1 Heating up to 85 C STEP 2 Cooling down to 4 C STEP 3 Maintaining at 4 C indefinitely MA MC In this phase beating is activated along with the compressor or for 10 seconds each 30 minute...

Страница 40: ...1 Heating up to 90 C STEP 2 Cooling down to 4 C STEP 3 Maintaining at 4 C indefinitely MA MC In this phase beating is activated along with the compressor or for 10 seconds each 30 minutes 90 C 4 Time...

Страница 41: ...ntaining at 65 for 30 At 65 pause is with beating on STEP 3 Cooling down to 4 C STEP 4 Maintaining at 4 C indefinitely MA MC In this phase beating is activated along with the compressor or for 10 seco...

Страница 42: ...ditable from 2 to 4 C STEP 2 Maintaining at 4 C indefinitely MA MC In this phase beating is started along with the compressor or for 10 seconds each 30 minutes Beating can be forced by pressing the Be...

Страница 43: ...UAL FUNCTIONS 15 SHOWER 19 SOFTWARE UPDATE 20 AUTOSETUP 21 PROCESS AUTOSETUP 22 EVENTS 23 Reading Pasteurization cycles 23 Reading Events 24 ELECTRONIC BOARD IMAGES 25 Connectors IC573700148 26 ALARMS...

Отзывы: