V. Commissioning the Air/Q 1100-Avian
A. Getting Started
1. Open the door and unlock if needed.
2. Turn on the power by pressing the ON/OFF button in the upper left corner of the control panel. (Make
sure the appliance is plugged in to the AC power outlet.) The power button will light blue.
B. Setting the Clock
1. Turn the dial to Set Clock. The time will blink.
2. Adjust the time forward or backward using the +/– buttons on the right side of the control panel. AM or
PM is indicated on the lower right side of the time digits. Hold + to fast forward.
C. Using the 24/7 Mode (recommended)
If you want the Air/Q™ 1100 to run continuously — 7 days a week, 24 hours a day — turn the dial to 24/7.
24/7 Mode is recommended because it is assumed that the openings which allow the entry of birds remain
even when the structure is not operational. If this is not the case, you can program AvianPlus™ to start and
stop at specific times of day, describe below in Using the Program Mode.
D. Using the Program Mode
1. Setting specific Start/Stop Times.
• Turn the dial to Start.
• Adjust the clock to the time you want the appliance to start each day using the +/– keys.
• Turn the dial to Stop.
• Adjust the clock to the time you want the appliance to stop each day using the +/– keys.
2. Turn the dial to Program to operate with the specified start/stop times.
E. Off Cycle
For intensity level settings 1-49, there will be a 7-minute off cycle at various intervals based on the setting.
Level 50 will be always on while in 24/7 mode or within the programmed operational period.
6
Commissioning the Air/Q 1100-Avian