Logging In to the Thermostat
Verifying the Thermostat’s Operating Status
This section describes the procedures you can use to verify that the heat, cool, and fan
controls are operating properly on your thermostat. Before you begin, verify that the
HVAC system’s power is set to “
On
” and
HVAC
on the thermostat lcd panel is set to
“
Auto”
.
Testing the Heat Controls
1
Verify the HVAC mode is set to either
Auto
or
Heat
.
2
Continuously press the
Up
arrow until the heat set point is higher than the temperature
reading.
A flame icon appears, and the HVAC system activates the heat.
Testing the Cool Controls
1
Verify the HVAC mode is set to either
Auto
or
Cool
.
2
Continuously press the
Down
arrow until the cool set point is lower than the
temperature reading.
A snowflake and fan icon appears, and the HVAC system activates the cool and fan.
Testing the Fan Operation
Press the fan button until the mode is set to
On
. A fan icon appears, and the fan circuit
is now active.
Logging In to the Thermostat
Log in to the TMI as the Administrator as follows:
1
Enter the username:
admin
.
2
Enter the password:
admin
(default).