Beta Draft Confidential
12
Proliphix Internet Managed Thermostat (IMT) Installation Guide, Release 1.0
Part No. 600-03100-000, Rev. 2
Installing and Wiring the Thermostat
Mounting the Thermostat into the Base Plate
The Proliphix thermostat contains jumpers to configure the HVAC power settings.
The power settings determine which HVAC power source (RH or RC) is configured
to turn on each HVAC system (cool, heat, and fan). Most applications use only RH
power. The Proliphix thermostat is shipped from the factory with the RH and RC
jumpered together.
Table 8
lists the possible HVAC power configurations.
Figure 7 Jumper Configuration
Table 8 HVAC Power Configuration
HVAC Power Configuration
Supplies...
RH only (default)
or
RC only
W1, W2, Y1, Y2, G
RH and RC Supplies separate
RH supplies W1, W2, G; RC supplies Y1 and Y2
RH and RC Supplies separate
RH supplies W1 and W2; RC supplies Y1, Y2, G